Affiliation:
1. Xi’an University of Posts & Telecommunications
2. Chinese Academy of Sciences
Abstract
In order to effectively improve the contrast of target identification, an acousto-optic tunable filter (AOTF) full-Stokes imaging spectropolarimeter is proposed, which can measure synchronously polarization information with each spectral band in real time. The full-Stokes vectors are obtained by the division-of-aperture polarization imaging system. The spectral bands are selected by RF of the AOTF electrically. Based on this system, a polarization error model is established, and the influence of the key polarization element angle error is analyzed. The results show that the measurement error increases with the increase of the polarization degree. When
P
=
1
, the influence of the azimuth angle error is greater than the retardance error under the same angle error. The results are helpful to find the variation law of the polarization error and provide a theoretical reference for the design of new types of full-Stokes imaging spectropolarimeters.
Funder
National Natural Science Foundation of China
Subject
Computer Vision and Pattern Recognition,Atomic and Molecular Physics, and Optics,Electronic, Optical and Magnetic Materials
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献