Estimation of the full shape of the crystalline lens from OCT: validation using stretched donor lenses

Author:

Martínez-Enríquez Eduardo1ORCID,Maceo Heilman Bianca23,de Castro Alberto1ORCID,Mohamed Ashik45ORCID,Ruggeri Marco2ORCID,Zvietcovich Fernando6ORCID,Manns Fabrice23,Marcos Susana17ORCID

Affiliation:

1. Instituto de Óptica

2. University of Miami School of Medicine

3. University of Miami College of Engineering

4. LV Prasad Eye Institute

5. Brien Holden Vision Institute

6. Pontificia Universidad Católica del Peru

7. University of Rochester

Abstract

Quantifying human crystalline lens geometry as a function of age and accommodation is important for improved cataract and presbyopia treatments. In previous works we presented eigenlenses as a basis of 3-D functions to represent the full shape of the crystalline lens ex vivo. Also, we presented the application of eigenlenses to estimate the full shape of the lens in vivo from 3-D optical coherence tomography (OCT) images, where only the central part of the lens -visible through the pupil- is available. The current work presents a validation of the use of eigenlenses to estimate in vivo the full shape of dis-accommodated lenses. We used 14 ex vivo crystalline lenses from donor eyes (11-54 y/o) mounted in a lens stretcher, and measured the geometry and the power of the lenses using a combined OCT and ray tracing aberrometry system. Ex vivo, the full extent of the lens is accessible from OCT because the incident light is not blocked by the iris. We measured in non-stretched (fully accommodated) and stretched (mimicking in vivo dis-accommodated lenses) conditions. Then, we simulated computationally in vivo conditions on the obtained ex vivo lenses geometry (assuming that just the portion of the lens within a given pupil is available), and estimated the full shape using eigenlenses. The mean absolute error (MAE) between estimated and measured lens’ diameters and volumes were MAE = 0.26 ± 0.18 mm and MAE = 7.0 ± 4.5 mm3, respectively. Furthermore, we concluded that the estimation error between measured and estimated lenses did not depend on the accommodative state (change in power due to stretching), and thus eigenlenses are also useful for the full shape estimation of in vivo dis-accommodated lenses.

Publisher

Optica Publishing Group

Subject

Atomic and Molecular Physics, and Optics,Biotechnology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3