Dual-channel air-pulse optical coherence elastography for frequency-response analysis

Author:

Song Chengjin,He Weichao,Feng Jinping1,Twa Michael D.2ORCID,Huang Yanping3,Xu Jingjiang3ORCID,Qin Jia3,An Lin3,Wei Xunbin45,Lan Gongpu3ORCID

Affiliation:

1. Institute of Engineering and Technology, Hubei University of Science and Technology

2. University of Houston

3. Guangdong Weiren Meditech Co., Ltd.

4. Peking University

5. Institute of Medical Technology

Abstract

Microliter air-pulse optical coherence elastography (OCE) has recently been proposed for the characterization of soft-tissue biomechanics using transient, sub-nanometer to micrometer-scale natural frequency oscillations. However, previous studies have not been able to provide real-time air-pulse monitoring during OCE natural frequency measurement, which could lead to inaccurate measurement results due to the unknown excitation spectrum. To address this issue, we introduce a dual-channel air-pulse OCE method, with one channel stimulating the sample and the other being simultaneously measured with a pressure sensor. This allows for more accurate natural frequency characterization using the frequency response function, as proven by a comprehensive comparison under different conditions with a diverse range of excitation spectra (from broad to narrow, clean to noisy) as well as a diverse set of sample response spectra. We also demonstrate the capability of the frequency-response analysis in distinguishing samples with different stiffness levels: the dominant natural frequencies increased with agar concentrations (181–359 Hz, concentrations: 1–2%, and maximum displacements: 0.12–0.47 µm) and intraocular pressures (IOPs) for the silicone cornea (333–412 Hz, IOP: 5–40 mmHg, and maximum displacements: 0.41–0.52 µm) under a 200 Pa stimulation pressure. These frequencies remained consistent across different air-pulse durations (3 ms to 35 ms). The dual-channel OCE approach that uses transient, low-pressure stimulation and high-resolution imaging holds the potential to advance our understanding of sample frequency responses, especially when investigating delicate tissues such as the human cornea in vivo.

Funder

National Natural Science Foundation of China

Guangdong Basic and Applied Basic Research Foundation

Guangdong Provincial Pearl River Talents Program

Guangdong Eye Intelligent Medical Imaging Equipment Engineering Technology Research Center

Guangdong-Hong Kong-Macao Intelligent Micro-Nano Optoelectronic Technology Joint Laboratory

National Eye Institute

Publisher

Optica Publishing Group

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370