Affiliation:
1. Changchun University of Science and Technology
Abstract
A three-axis angle measurement method is proposed using an optical wedge as a
reflector. In this paper, the mathematical model of three-axis angle
solving corresponding to the method is derived, and it is verified and
corrected by establishing an optical simulation model, and, finally,
the feasibility and measurement accuracy of the method are verified by
using a principle prototype. The experimental results show that the
RMS values of the measurement errors of pitch angle α, yaw angle β, and roll angle γ are 6.27′′, 4.35′′, and 17.68′′, respectively, within the measurement
range of ±2∘, and the measurement accuracy is
insensitive to the measurement distance.
Funder
National Natural Science Foundation of China