Retinal magnification factors at the fixation locus derived from schematic eyes with four individualized surfaces

Author:

Huang Xiaojing12ORCID,Anderson Trevor3,Dubra Alfredo2ORCID

Affiliation:

1. University of Rochester

2. Stanford University

3. Cylite Pty. Ltd.

Abstract

Retinal magnification factors (RMFs) allow the conversion of angles to lengths in retinal images. In this work, we propose paraxial and non-paraxial RMF calculation methods that incorporate the individual topography and separation of the anterior and posterior surfaces of the cornea and crystalline lens, assuming homogeneous ocular media. Across 34 eyes, the two RMF methods differ by 0.1% on average, due to surface tilt, decenter, and lack of rotational symmetry in the non-paraxial modeling, which results in up to 2.2% RMF variation with retinal meridian. Differences with widely used individualized RMF calculation methods are smallest for eyes with ∼24 mm axial length, and as large as 7.5% in a 29.7 mm long eye (15D myope). To better model the capture of retinal images, we propose the tracing of chief rays, instead of the scaling of posterior nodal or principal distances often used in RMF definitions. We also report that RMF scale change is approximately proportional to both refractive error and axial separation between the ophthalmoscope’s exit pupil and the eye’s entrance pupil, resulting in RMF changes as large as 13% for a 1cm displacement in a 15D myopic eye. Our biometry data shows weak correlation and statistical significance between surface radii and refractive error, as well as axial length, whether considering all eyes in the study, or just the high myopes, defined as those with refractive error sphere equivalent ≤ -4D. In contrast, vitreous thicknesses show a strong correlation (r ≤ -0.92) and significance (p ≤ 10−13) with refractive error when considering all eyes or just high myopes (r ≤ -0.95; p ≤ 10−5). We also found that potential RMF change with depth of cycloplegia and/or residual accommodation is smaller than 0.2%. Finally, we propose the reporting of individual ocular biometry data and a detailed RMF calculation method description in scientific publications to facilitate the comparison of retinal imaging biomarker data across studies.

Funder

National Eye Institute

Stanford Center for Optic Disc Drusen at the Byers Eye Institute

Research to Prevent Blindness

Publisher

Optica Publishing Group

Subject

Atomic and Molecular Physics, and Optics,Biotechnology

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3