Affiliation:
1. Beihang University
2. Hangzhou Innovation Institute, Beihang University
3. Research Institute for Frontier Science, Beihang University
Abstract
The magnitude of the electron spin-relaxation rate Rrel of the atomic ensemble directly affects the sensitivity of the spin-exchange relaxation-free (SERF) atomic magnetometer (AM). The rapid and in-situ characterization of Rrel is of great importance. In this work, a fast extraction method of Rrel is proposed with a measurement period shorten to 0.5 s, merely detecting the transient response of SERF AM to a transverse DC excitation magnetic field after switching off the pump beam. In contrast to the conventional methods based on the measurement of the magnetic resonance linewidth, this method circumvents the involvement of optical pumping rate, and enables monitoring Rrel under arbitrary polarization, which is expected to improve the authenticity of Rrel measurement in a more convenient way.
Funder
National Key Research and Development Program of China
National Natural Science Foundation of China
Subject
Atomic and Molecular Physics, and Optics
Cited by
11 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献