Affiliation:
1. Chinese Academy of Sciences
2. University of Chinese Academy of Sciences
3. National Optical-Infrared Astronomy Research Laboratory
Abstract
The accurate infrared solar magnetic field measurement system (AIMS) is a 1 m off-axis Gregorian alt-azimuth solar telescope and will be dedicated to measuring the solar magnetic field in mid-infrared. How to align the large-aperture off-axis system is a significant issue. Sub-aperture stitching with the small-aperture standard flat mirror can be applied to the alignment of the large-aperture off-axis system. However, this method is time-consuming and inefficient. We propose an alignment method based on the Zernike polynomials of the central small aperture to solve the low efficiency of sub-aperture stitching. Theoretical simulation shows that the RMS residual error of the system after using the central small-aperture alignment method will be less than
4.5
∗
1
0
−
6
λ
at 632.8 nm. Practical alignment suggests that our method can make the RMS value of full-aperture wave aberration quickly converge to
0.12
λ
at 632.8 nm. Compared with the sub-aperture stitching method, our method can significantly reduce the times of sub-aperture stitching and save the alignment time.
Funder
National Natural Science Foundation of China
The Strategic Pioneer Program on Space Science, Chinese Academy of Sciences
Youth Innovation Promotion Association
Subject
Atomic and Molecular Physics, and Optics,Engineering (miscellaneous),Electrical and Electronic Engineering
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献