Abstract
The row scanning mechanism of a rolling shutter camera can be used to infer high-frequency information from a low-frame-rate video. Combining the high intensity of laser speckle and high row-sampling rate of a rolling shutter, extreme detectable vibration frequency limited by rolling shutter camera imaging is experimentally demonstrated. Using a commercially available industrial camera at a frame rate of 70 fps, a vibration signal with a frequency of 14.285 kHz is extracted that corresponds to an inter-row sampling period of 35 µs and a sampling frequency of 28.57 kHz. Connected component and centroid alignment algorithms are used to extract the inter-row vibration displacement. The parameters that limit the highest and lowest detectable frequencies are discussed.
Funder
National Natural Science Foundation of China
Subject
Atomic and Molecular Physics, and Optics
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Rolling-shutter laser speckle analysis in bio-photonics;Biomedical Spectroscopy, Microscopy, and Imaging III;2024-06-20