Affiliation:
1. Yunnan Observatories, Chinese Academy of Sciences
2. Kunming Institute of Physics
3. Shenzhen Polaris Technology Innovation Research Institute
Abstract
Non-contact temperature measurement for a solar telescope mirror is critical for improving the mirror seeing and thermal deformation of solar telescopes, a long-standing challenge in astronomy. This challenge arises from the telescope mirror’s inherent weak thermal radiation, often overwhelmed by reflected background radiations due to its high reflectivity. In this work, an infrared mirror thermometer (IMT) is equipped with a thermally-modulated reflector, and a measurement method based on an equation for extracting mirror radiation (EEMR) has been developed for probing the accurate radiation and temperature of the telescope mirror. Using this approach, we can extract the mirror radiation from the instrumental background radiation via the EEMR. This reflector has been designed to amplify the mirror radiation signal incident on the infrared sensor of IMT, while inhibiting the radiation noise from the ambient environment. In addition, we also propose a set of evaluation methods for IMT performance based on EEMR. The results reveal that the temperature measurement accuracy of IMT to the solar telescope mirror using this measurement method can be achieved better than ±0.15°C.
Funder
National Natural Science Foundation of China
Subject
Atomic and Molecular Physics, and Optics
Cited by
1 articles.
订阅此论文施引文献