Assessment of xenon-induced depth of hypnosis according to Kugler’s scale in elderly and senile patients undergoing knee replacement surgery: a prospective open-label cohort study

Author:

Lisichenko Ivan A.1ORCID,Gusarov V. G.1ORCID,Teplykh B. A.1ORCID,Chayanov N. V.2ORCID,Zamyatin M. N.1ORCID

Affiliation:

1. Pirogov National Medical and Surgical Center, Moscow, Russia

2. OOO ATES MEDICA soft, Moscow, Russia

Abstract

INTRODUCTION. Anesthesia with xenon is characterized by stable hemodynamic parameters, cardio- and neuroprotection preferable in elderly. Assessment of the depth of hypnosis remains challenging. The Kugler classification based on electroencephalogram has been suggested for such assessment. OBJECTIVES. To assess the feasibility of Kugler scale for objective assessment of the depth of hypnosis induced by xenon alone or in combination with narcotics and regional anesthesia during knee arthroplasty in elderly. MATERIALS AND METHODS. The study included 57 patients divided into 2 groups. In group 1, general anesthesia with xenon was performed, fentanyl and femoral nerve block were used for pain control. In group 2, xenon anesthesia was performed in combination with femoral and sciatic nerve block. The depth of hypnosis was monitored using EEG and matched with the Kugler scale. Also, the bispectral index (BIS) was recorded. RESULTS. At xenon concentration of 40 %, the depth of hypnosis reached D2 stage in group 1 and D1 in group 2 patients, while at 55 % and above it was D2 in both groups. Fentanyl increased the δ-rhythm by 19.08 %, which corresponded to reduction in the effective xenon concentration by 20 %. A correlation between δ-rhythm decrease and BIS was seen in groups 1 (r = –0.78; R2 = 60 %) and 2 (r = –0.61; R2 = 37 %). The differences could be related to the use of fentanyl in group 1. The intergroup difference between the reduction of BIS was not significant. CONCLUSIONS. In elderly patients undergoing knee arthroplasty under combined anesthesia, stage D2 according to Kugler scale (proportion of δ-rhythm more than 50 %) is achieved at xenon concentration of 55 % without narcotics and at concentration of 40 % with fentanyl. The diminished correlation between δ-rhythm and BIS in group 2 and no difference in decrease of BIS suggests that BIS is less accurate for determining the depth of hypnosis during xenon monoanesthesia.

Publisher

Practical Medicine Publishing House

Subject

Law,Anesthesiology and Pain Medicine,Critical Care and Intensive Care Medicine,Emergency Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3