Hemocompatibility of Polysulfone Hemodialyzers – Exploratory Studies on Impact of Treatment Modality and Dialyzer Characteristics

Author:

Wagner Stephan,Zschätzsch Sebastian,Erlenkoetter Ansgar,Rauber Lena,Stauss-Grabo Manuela,Gauly AdelheidORCID

Abstract

BackgroundThe hemocompatibility of dialyzers for extracorporeal kidney replacement therapy (KRT) is of importance to minimize harmful reactions between blood constituents and the membrane. We investigated in these exploratory studies the hemocompatibility profile of several types of polysulfone dialyzers.MethodsHemocompatibility of various high-flux polysulfone dialyzers were compared in two consecutive, prospective, randomized, crossover studies, each including 24 adult patients being at least 3 months on hemodialysis (HD) or on-line hemodiafiltration (HDF). These dialyzers, differing in membrane type, fiber geometry, sterilization method, and production technology, were each applied for 1 week in HD or HDF. Hemocompatibility was assessed through markers of complement activation, cell activation, coagulation, contact activation, and immunologic reactions.ResultsThe patients in the two studies were on average 67±11 and 68±11 years old, 75% and 67% were male, and were on KRT for 5.4±5.0 and 4.4±3.6 years. The complement factors C3a and C5a increased early and transiently during treatment, less so with HDF than with HD, and with dialyzers combining wider inner fiber diameter (210 versus 185 µm) and advanced membrane type (Helixone plus versus Helixone). sC5b-9 increased in all study phases, reaching its highest level after 60 minutes, with lower values over the entire treatment (area under the curve) for HDF than HD, and for wider inner fiber diameter and advanced membrane type. Leukocytes decreased in the first 10 minutes, without significant differences between dialyzers. PMN elastase increased in the first hour, more so with HD than HDF. Thrombocytes decreased slightly in the first 30 minutes, with differences only between HDF and HD mode. IL-8 decreased from pre- to postdialysis, particularly on HDF. No differences were observed for kallikrein, IgE, and hsCRP.ConclusionsIn these explorative studies we found indications to a comparable hemocompatibility profile of the investigated dialyzers. We observed distinctions in compounds between HDF and HD and for some dialyzer and membrane characteristics.

Funder

Fresenius Medical Care

Publisher

American Society of Nephrology (ASN)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3