Abstract

Key Points A single bolus of tinzaparin is effective for 8-hour hemodialysis session.Eight-hour simulation sessions with anti-Xa monitoring are useful to adjust tinzaparin dose. Background Few studies have assessed the use of low-molecular weight heparins for anticoagulation during extended hemodialysis (HD) sessions. This study aimed to evaluate the efficacy of a single bolus of tinzaparin for anticoagulation of the extracorporeal circuit and dialyzer in 8-hour HD sessions. Methods This single-center study included all patients who underwent a single 8-hour simulation session as part of their nocturnal home HD training between 2009 and 2020. Tinzaparin was delivered as a single-bolus injection at time 0 with dosing on the basis of doubling of standard 4-hour session dose. Tinzaparin efficacy was examined using visual observations (score 1–4) of the dialyzer and venous bubble trap at the end of dialysis and using anti-Xa measured at 15 and 30 minutes and 1, 2, 4, 6, and 8 hours after HD start. Results Forty-seven patients were included. The mean tinzaparin dose was 107±20 IU/kg. Anti-Xa levels peaked at 15 minutes with 1.3±0.4 IU/ml and progressively declined reaching 0.9±0.3 IU/ml at 1 hour, 0.4±0.21 IU/ml at 4 hours, and 0.15±0.15 IU/ml at 8 hours. After the 8-hour session, none of the patients had severe clotting of their dialyzer or venous chamber. Moderate blood clotting was observed in the dialyzer of 6 patients (20%) and in the venous chamber of 22 patients (61%). On the basis of the simulation results, tinzaparin dose was increased in 27 patients (58%) with a mean home-discharge dose of 123±28 IU/kg. Conclusions This study shows that anti-Xa levels stabilized rapidly after administration of tinzaparin for 8-hour HD. Administration of a single-bolus tinzaparin at the start of an 8-hour dialysis session seemed effective, although dose adjustment may be required.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Psychiatry and Mental health,Neuropsychology and Physiological Psychology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3