A research on rigid polyurethane foam resistibility to ignition from an electric arc welding spark

Author:

Poletaev N. L.1ORCID

Affiliation:

1. All-Russian Research Institute for Fire Protection of Ministry of Russian Federation for Civil Defense, Emergencies and Elimination of Consequences of Natural Disasters

Abstract

Introduction. A fire investigation assumes that electric arc welding sparks (hereinafter referred to as “sparks”) are effective sources of ignition. However, the spark ignition of a combustible material depends on the contact time. This work has experimentally proven that a smooth vertical wall, made of combustible rigid polyurethane foam (PUF), is not subjected to spark ignition. To explain this fact, the author calculated the time of contact between the spark and the wall τint, and compared it with the minimal estimated contact time τmin required to ignite the wall.The sample and the testing procedure. Sparks (the arc power up to 6 kW, the current up to 160 A) reached the PUF wall located at a distance of 0.1–0.15 m from the arc. An everyone experiment was continued until the electrode was burned down.Research results and discussion. Neither attempt to inflame the PUF sample by a spark was successful. Sparks bounced off the PUF sample and fell down. The characteristic dimensions of cooled iron droplets ranged from 0.2 to 3 mm.An evaluation of τint. The authors applied a model of elastic interaction between a drop of molten iron and a rigid wall, assuming that the sum of the potential energy of the drop, associated with its surface, and the kine­tic energy of a spreading drop, if flattened, is conserved. The longest contact time is achieved for drops, featuring the maximum diameter of 3 mm: τint ≈ 0.004 s.Estimation τmin. The authors applied the experimental modeling of the process, whereby the effect of an iron drop on PUF was replaced by the time-controlled effect, produced by a wooden cylinder (6 mm in diameter), inflamed at one edge. τmin ≈ 0.3 s. The ratio τint << τmin explains the inability of electric arc welding sparks to ignite the PUF wall.Conclusions. Electric arc welding sparks, having a diameter of up to 3 mm, cannot ignite a vertical wall, made of rigid combustible polyurethane foam, in case of a side impact. The lack of ignition is explained by the short-term contact between the spark and the surface of the polyurethane foam.

Publisher

Moscow State University of Civil Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3