Comparison between MyoRing and 355°KERATACx in the management of keratoconus

Author:

Edrees Eman S.M.,Zaher Fekry M.F.,Assaf Ahmed H.S.,Yousef Mohamed O.,Ebeid Ahmed A.A.

Abstract

Background Intracorneal implants have been proposed over the years as a possible easier way for managing keratoconus, having a favorable influence on the course of the disease. KERATACx is a relatively new form of intracorneal ring segments that has been recently introduced but not thoroughly studied regarding its safety and efficacy. Moreover, implanting a complete intrastromal ring into a corneal pocket, MyoRing (Dioptex GmbH, Austria), is an alternative technique, which can be considered safe, effective, and relatively easy for the treatment of keratoconus. Aim To compare between the effect of MyoRing and KERATACx corneal implants as new modalities of treatment on the visual acuity, as well as assess corneal topography findings in cases with moderate to severe keratoconus. Patients and methods Our study is a prospective comparative study conducted at specialized eye centers in Cairo. A total of 20 keratoconic eyes were eventually recruited. Overall, 10 of those eyes had 355° intracorneal ring segment implants (KERATACx ring segments) inserted into a femtosecond laser-created corneal tunnel at a depth of 75% of the thinnest location at the proposed tunnel site (group A), whereas the other 10 eyes had complete ring (MyoRing) implantation into a femtosecond laser-created corneal pocket at a 300-μm corneal depth (group B), by the same designated surgeon. The study was approved by the Ethics Committee of Ain-Shams University. Results Both types were proven to be statistically effective, with no statistically significant differences between the two groups related to any of the followed up parameters. In fact, both proved safe, effective, and reliable methods for managing keratoconus, with no difference of importance even to the degree of myopic refractive error correction. There were no significant intraoperative or postoperative complications reported within both groups throughout the whole study and follow-up period, but in turn, stability of the achieved results was found in both groups. Conclusion Both MyoRing and KERATACx were found to be equally effective, safe, and reliable methods for keratoconus management.

Publisher

Medknow

Reference15 articles.

1. Aetiology of keratoconus;Karseras;Br J Ophthalmol,1976

2. A 48-year clinical and epidemiologic study of keratoconus;Kennedy;Am J Ophthalmol,1986

3. Correcting keratoconus with intracorneal rings;Colin;J Cataract Refract Surg,2000

4. Intracorneal continuous ring implantation for keratoconus: one year follow-up;Daxer;J Cataract Refract Surg,2010

5. Biomechanics of corneal ring implants;Daxer;Cornea,2015

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3