Abstract

ABSTRACT Objective: This study aims to evaluate the radiobiological benefits among the different radiotherapy (RT) planning techniques for esophageal squamous cell carcinoma (ESCC). Materials and Methods: In this experimental study, 35 patients with ESCC cancer were planned for the field-in-field (FIF), three fields (3Fs), and four-field boxes were performed for each patient for a 6 MV photon beam. The parameters of the conformity index (CI), homogeneity index (HI), Dmean, Dmax, tumor control probability (TCP), V20Gy, and V30Gy of the heart and lungs, and normal tissue complication probability (NTCP) were analyzed to evaluate treatment plans. Dose distribution in the target volume, the monitor units (MUs) required, and the dose delivered to organs at risk (OARs) were compared for these techniques using the paired-sample t-test. Results: A significant difference was measured between the FIF, 3F, and 4F techniques with respect to CI, dose HI, and TCP for the target organ, as well as the Dmean for the heart and liver. For the spinal cord, the FIF technique showed a slight reduction in the maximum dose compared to the other two techniques. In addition, the V20Gy of the lungs and the NTCP of all OARs were reduced with the FIF method. Conclusion: The FIF technique showed better performance in terms of dose homogeneity in the target, conformity of the radiation field with the target volume, TCP, less dose to healthy organs, and fewer MU, which could improve the TCP and spare the heart, lungs, and spinal cord. Our study provides a prediction of RT outcomes and further guides the individual treatment.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3