Tolerance to preoperative placement of electrodes for neuromuscular monitoring using the Tetragraph™

Author:

Espinal Leah M.1,Kalsotra Sidhant2,Rice-Weimer Julie2,Kitio Sibelle A. Yemele2,Tobias Joseph D.23

Affiliation:

1. Heritage College of Osteopathic Medicine - Dublin Campus, Dublin, Ohio and Ohio University, Athens, Ohio, USA

2. Department of Anesthesiology and Pain Medicine, Nationwide Children’s Hospital, Columbus, Ohio, USA

3. Department of Anesthesiology and Pain Medicine, The Ohio State University College of Medicine, Columbus, Ohio, USA

Abstract

Background: Quantitative train-of-four (TOF) monitoring has recently been shown to be feasible in infants and children using a novel electromyography (EMG)-based monitor with a pediatric-sized self-adhesive sensor. However, placement of the sensor and initiation of TOF monitoring may require additional time in the operating room (OR), delaying workflow and the time to induction of anesthesia. The current study evaluates the feasibility of placing the self-adhesive sensor in the preoperative holding area in pediatric patients before arrival to the OR. Methods: Consented pediatric patients undergoing inpatient surgery requiring the administration of NMBAs were enrolled. The EMG electrode was placed along the ulnar nerve on the volar aspect of the distal forearm to provide neurostimulation. After the induction of anesthesia, monitoring was initiated and TOF recording started before the administration of the NMBA. A Likert score (0-10) was used to assess ease of placement, tolerability of the monitor during the preoperative period, and its ability to generate a recorded response in the OR. Results: The final study cohort included 40 patients with a median age of 3.7 years. Fourteen patients (35%) pulled off the sensor before arrival to the OR and 26 patients (65%) arrived at the OR with the sensor intact and functioning. Older children were more likely to maintain the sensor until arrival to the OR compared to younger patients (median age of 5.24 versus 1 year, P = 0.0521). A median age of 3.7 years correlated with an 80% chance of arriving in the OR with the sensor intact. Application ease and tolerance of the sensor were higher in the group that maintained the sensor until OR arrival. Conclusion: In patients more than 4 years of age, placement of the self-adhesive sensor for EMG-based TOF monitoring may be feasible. However, in younger patients, additional interventions may be required to achieve a similar success rate.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3