Estimating the skin dose near to the applicator and acute toxicity in breast cancer patients: An intraoperative electron radiotherapy technique

Author:

Mirkazemi Maryam Sadat1,Mahdavi Seyed Rabi2,Nafissi Nahid3,Monfared Ali Shabestani4,Ghoreishi Seyedeh Masoumeh5,Gorji Kourosh Ebrahimnejad1

Affiliation:

1. Department of Medical Physics, Babol University of Medical Sciences, Babol University of Medical Sciences, Babol, Iran

2. Department of Medical Physics, Iran University of Medical Sciences, Tehran, Iran

3. Surgical Department, School of Medicine, Iran University of Medical Sciences, Tehran, Iran

4. Cancer Research Center, Health Research Institute, Babol University of Medical Sciences, Babol, Iran

5. Cellular and Molecular Biology Research Center, Health Research Institute, Babol University of Medical Sciences, Babol, Iran

Abstract

ABSTRACT Introduction: Intraoperative electron radiation therapy (IOERT) is one of the most recently popular therapeutic methods for breast cancer. This study aimed to measure the skin dose near the applicator during IOERT of breast cancer patients, as well as, the incidence of acute toxicity after surgery. Materials and Methods: Thirty-six female patients participated in the current study with the prescribed dose of 21 and 12 Gy for IOERT as full and boost, respectively. The skin dose was investigated based on different applicator sizes, tumor bed thicknesses, and monitor units (MUs). The energy was chosen 8 MeV, and EBT3 film was used for the dosimetric process. In addition, the acute toxicity included healing time for the surgical wound, scaling of the skin, itching, necrosis, redness as well as seroma formation for 1 week and 1 month were recorded. The results were compared to those of 22 patients who underwent the surgery without IOERT. Results: The highest skin dose for the patients was obtained 2.09 Gy, which is lower than the threshold dose (6 Gy). Furthermore, the findings showed that the average skin dose was higher in bigger applicator sizes and MU and lower tumor bed thicknesses. The average of wound healing for the patient underwent IOERT and without the use of IOERT (as the control group) was 19.32 and 11.67 days, respectively. One month after surgery, the volume of aspirated seroma was higher in the patients who performed IOERT compared to the control group (250 ml vs. 200 ml). It is notable that there were not observed any redness, itching, scaling, and necrosis in both investigated groups. Conclusion: Owing to the results, the skin dose during IOERT was lower than the recommended level. The dose of IOERT as a full was higher than boost which can be related to the lower number of the patients in full method; however, there was a well-tolerated without severe acute complication, especially seroma formation and wound healing time in both full and boost methods.

Publisher

Medknow

Subject

Radiology, Nuclear Medicine and imaging,Oncology,General Medicine

Reference29 articles.

1. Graphene as cancer theranostic tool:Progress and future challenges;Orecchioni;Theranostics,2015

2. Dosimetric comparison of four different techniques for supraclavicular irradiation in 3D-conformal radiotherapy of breast cancer;Firouzjah;Health Phys,2019

3. Dosimetric comparison of artificial walls of bladder and rectum with real walls in common prostate IMRT techniques:Patient and Monte Carlo study;Gorji;J Xray Sci Technol,2020

4. Dosimetric comparison of level II lymph nodes between mono-isocentric and dual-isocentric approaches in 3D-CRT and IMRT techniques in breast radiotherapy of mastectomy patients;Nadi;J Radiother Pract,2019

5. Intraoperative radiotherapy:Review of techniques and results;Pilar;Ecancermedicalscience,2017