Low-dose radiation therapy for COVID-19 pneumonia: Comparison of dosimetry and life-time attributable risk of cancer with conventional AP-PA fields and bone marrow sparing VMAT

Author:

Sharma Daya Nand1,Sharma Seema1,Gupta Anil1,Saini Surendra Kumar1,Subramani Vellaiyan1

Affiliation:

1. Department of Radiation Oncology, All India Institute of Medical Sciences, New Delhi, India

Abstract

ABSTRACT Purpose: Low-dose radiation therapy (LDRT) to lungs did show encouraging results in COVID-19 patients in some clinical trials. However, there has been some concern regarding the long-term risk of radiation-induced cancer (RIC). Compared to the conventional AP-PA field technique, volumetric modulated arc therapy (VMAT) can potentially reduce the dose to the marrow and other organs at risk (OARs) and thus minimize the risk of cancer. We designed a dosimetry study to study if VMAT can reduce the exposure to the marrow and other OAR doses and curtail the estimated life-time attributable risk (LAR) of cancer. Methods and Materials: We retrieved the computed tomography scan data of 10 patients (aged 40–60 years, median 48 years) who have been already treated for any malignancy in the region of the thorax. A dose of 1.0 Gy in single fraction was prescribed to both lungs. All the organs were delineated as per the established guidelines. The dosimetry achieved by the two plans was compared to find the difference. Mean OAR doses were used to estimate the LAR for both plans and compared. Results: Planning target volume coverage parameters like conformity index and homogeneity index were significantly better with VMAT (P value < 0.05 for all). The mean dose to most OARs was significantly lower with VMAT (P value < 0.05 for all). The mean dose to the marrow was significantly lower with VMAT (59.05 vs 81.9 cGy with P value < 0.05). The overall LAR was significantly lower with VMAT as compared to the conventional plan (0.357% vs 0.398%, P value < 0.05). Conclusion: Compared to the conventional technique, VMAT provides better OAR dosimetry for lung irradiation (a prescription dose of 1.0 Gy or more) in COVID-19 pneumonia. VMAT significantly reduces the risk of RIC. We therefore suggest if lung LDRT is used for COVID-19 patients, VMAT is the preferred technique for a prescription dose of ≥1.0 Gy.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3