Can dysphagia aspiration related structures (DARS) be spared in patients with oropharyngeal cancers? Dosimetric evaluation in a prospective study of DARS optimized intensity modulated radiation therapy

Author:

Calcuttawala Adnan12,Shinghal Abhishek13,Budrukkar Ashwini N.1,Swain Monali1,Murthy Vedang1,Laskar Sarbani G.1,Gupta Tejpal1,Upereti Rituraj4,Kale Shrikant4,Agarwal Jai Prakash1

Affiliation:

1. Department of Radiation Oncology, Tata Memorial Hospital, Homi Bhabha National Institute, Parel, Mumbai, India

2. Department of Radiaiton Oncology, Mahatma Gandhi Cancer Hospital, Miraj, Maharashtra, India

3. Department of Radiaiton Oncology, Mahanama Pandit Madanmohan Malaviya Cancer Centre, Varanasi, Uttar Pradesh, India

4. Department of Medical Physics, Tata Memorial Hospital, Homi Bhabha National Institute, Parel, Mumbai, India

Abstract

ABSTRACT Purpose: To evaluate the feasibility of sparing the dysphagia-aspiration-related structures (DARS) in various head and neck cancer sites treated with definitive DARS-optimized intensity modulated radiation therapy (IMRT) and concurrent chemotherapy. Materials and Methods: Target volumes, organs at risk, and in addition, individual DARS were delineated, including the superior, middle, and inferior pharyngeal constrictor muscles, supraglottic and glottic larynx, the base of the tongue, esophageal inlet muscles and cervical esophagus in 35 patients with head and neck squamous cell carcinoma. Volume-based dose constraints were applied to the DARS outside the planning target volume (PTV). An IMRT plan was then generated to limit doses to DARS without compromising PTV dose coverage. Results: Twelve (34.3%) patients had an oropharyngeal primary (OPX), 18 (51.4%) had a laryngeal, and 5 (14.3%) patients had hypopharyngeal primary. The mean dose to the DARS was 47.93 Gy for the entire group, while it was 54.6 Gy in oropharyngeal primaries and 44.4 Gy in laryngopharyngeal primaries. DARS mean dose of ≤45 Gy could be achieved in a significantly lesser number of patients with oropharyngeal primaries (P < 0.02). Similarly, DARS mean dose was 42.25 Gy in patients with N0 disease, 49.6 Gy with ipsilateral involved nodes, and 55 Gy with bilateral disease. Sparing of DARS was feasible when the volume of PTV was ≤150 cc (P < 0.025). Conclusion: Sparing of DARS structures appears to be challenging in patients with oropharyngeal cancers without compromising the dose to the PTVs while it is feasible in laryngopharyngeal cancers. DARS sparing is feasible when the PTV volume is < 150 cc and in patients with negative or unilateral nodal disease.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3