Stereotactic radiosurgery in India: A nationwide survey of technology and quality assurance practices

Author:

Patwe Parimal T.12,Deshpande Sudesh3,Chaudhari Suresh4,Mahajan Gajanan R.5

Affiliation:

1. School of Physical Sciences, Swami Ramanand Tirth Marathwada University, Hadgaon, Nanded, Maharashtra, India

2. Department of Radiation Oncology, National Cancer Institute, Nagpur, Maharashtra, India

3. Department of Radiation Oncology, P.D. Hinduja Hospital and Medical Research Centre, Mumbai, Maharashtra, India

4. Department of Radiation Oncology, American Oncology Institute, Hydrabad, Telangana, India

5. Department of Physics, Shri Datta Arts, Commerce and Science College, Hadgaon, Nanded, Maharashtra, India

Abstract

ABSTRACT Purpose: India is rapidly adopting advanced treatments like Stereotactic Radiosurgery (SRS). However, there is a paucity of data on SRS practice. The aim of study is to assess the current status of technology and practices of machine quality assurance (QA) and patient specific quality assurance for SRS in India. Materials and Methods: A survey questionnaire was designed using Google Forms and sent to chief/senior medical physicists across 220 radiotherapy centers in India on July 15, 2022. It contained questions on infrastructure availability, treatment planning, and QA. Results: SRS was found to be extensively used for the treatment of brain metastases (99.3%), followed by meningioma (50.3%), acoustic neuroma (45.5%), and pituitary tumours (33.1%). The most commonly used photon energy and treatment technique were 6MV FFF and VMAT, respectively. A prescription isodose line ranging from 70% to 100% was selected by linac users. Most linac institutes verify pretreatment doses. There was a lack of uniformity in the analysis metrics such as Low Dose Threshold, Dose Difference, and Distance to Agreement. A survey revealed that the variety of SRS QA programs being followed at Indian radiotherapy centers. Conclusion: This is the first study to report the physics practice of SRS in India. The survey shows a need to carry out a postal dose audit for small static photon fields in India.

Publisher

Medknow

Subject

Radiology, Nuclear Medicine and imaging,Oncology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3