Predictors of cardiac dose sparing in deep inspiratory breath-hold technique for radiation of left breast cancer patients

Author:

Nagpal Puneet1,Pruthi Deep Shankar1,Shanmugam Prabakar1,Pandey Manish Bhushan1,Singh Harpreet1

Affiliation:

1. Department of Radiation Oncology, Action Cancer Hospital, New Delhi, India

Abstract

ABSTRACT Introduction: Radiation therapy to left breast cancer patients results in significant exposure to heart resulting in long-term cardiac morbidity. This exposure can be reduced by performing deep inspiratory breath-hold (DIBH) technique, however, patient selection criteria or predictive parameters are not routinely used which can identify patients who will have significant benefit with this technique. This study intends to find and use these predictive parameters measured on free-breathing (FB) simulation scan which can help to select such patients so as to develop our institutional protocol. Methods: A total of 35 patients of left breast cancer postsurgery were recruited in the study. All patients underwent 2–3 sessions of DIBH coaching followed by planning computed tomography scan in both FB phase and DIBH phase. Various anatomical parameters such as cardiac contact distance parasagittal (CCDps), CCD axial, heart–chest distance (HCD), and D were measured on FB scan and were correlated with a mean heart dose achieved in DIBH scan. Results: Dose to normal structures, namely heart and lung, was drastically reduced for DIBH scan over FB scan. V5, V10, and V20 of heart also followed a similar reduction. The mean dose to heart in FB scan was 5.34 Gy, while in DIBH scan, it was 2.79 Gy which was statistically significant. Among all the parameters measured, CCDps and D had a statistically significant positive correlation with the mean heart dose in DIBH phase while HCD had a negative correlation which was statistically significant. Conclusion: Cardiac parameters on FB scan such as CCDps, HCD, and D predict the patients with usual cardiac risk who will benefit most with DIBH techniques setting an arbitrarily cutoff value.

Publisher

Medknow

Subject

Radiology, Nuclear Medicine and imaging,Oncology,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3