Normative Value of Accommodative Convergence to Accommodation in Indian Population Measured by Heterophoria Method

Author:

Singh Archana Dharmdeo1,Vannadil Harikrishnan2,Bhatta Sunandan3

Affiliation:

1. Department of Ophthalmology, INHS Kalyani, Visakhapatnam, Andhra Pradesh, India

2. Director and Consultant, Eyeris Eye Care, Secunderabad, Telangana, India

3. Department of Ophthalmology, Base Hospital, Srinagar, Jammu and Kashmir, India

Abstract

Abstract Introduction: Near response is a complex synkinesis required for a good binocular vision. accommodative convergence per diopter of accommodation (AC/A ratio) is a value of significance in this synkinetic movement. In addition, the value is used to classify and treat ocular movement abnormalities. The two commonly used methods for determining the AC/A ratio are Gradient Method and Heterophoria method. The normative data for Indian population by gradient method was described in two studies. However, the normative data for heterophoria method is lacking in Indian population. Objective: The purpose of this cross-sectional study is to generate the normative value for AC/A ratio for the Indian population by heterophoria method. One hundred healthy ophthalmologically normal adults with no presbyopia or refractive error were chosen consecutively among the attendants of patients visiting the center. Materials and Methods: After thorough ophthalmic evaluation, the participants were subjected to AC/A ratio calculation by heterophoria method using 6/9 fixation target and PMMA Prism bar. Results: One hundred healthy adults with no refractive error or ocular abnormality were selected with a mean age of 25.70 years (standard deviation [SD] = 4.92) and equal gender distribution. The mean Inter Pupillary Distance (IPD) was found to be 62.88 mm with a SD of 3.91 mm. The average phoria at distance was 1.82 prism diopters (SD = 2.03pd) of exophoria and for near at 33 cm was 4.20pd (SD = 1.92pd). The mean AC/A ratio by heterophoria method was found to be 5.49PD/D with an SD of 0.54PD/D. The highest being 6.90PD/D and the lowest being 4.27PD/D with no statistically significant difference between genders. Conclusion and Relevance: According to the previous studies, the normative data arrived is lesser than the value reached in the current study for similar population groups when considering both methodologies of testing. This variation between the gradient method and heterophoria method accounted for by the involvement of proximal convergence during the heterophoria method.

Publisher

Medknow

Reference18 articles.

1. Accommodative-convergence over accommodation (AC-A) ratio (in normal Indian subjects);Sen;Indian J Ophthalmol,1972

2. The gradient AC/A ratio:What's really normal?;Jackson;Am Orthopt J,2004

3. AC/A ratio;Hughes;Br J Ophthalmol,1967

4. Validity of clinical measures of the AC/A ratio;Bhoola;Clin Exp Optom,1995

5. Derivation of two critical appraisal scores for trainees to evaluate online educational resources:A METRIQ study;Chan;West J Emerg Med,2016

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370