Evaluation and Comparison of the Dimensional Accuracy of Resultant Casts Made by Monophase Polyether and Monophase Addition Silicone Impression Materials − An In Vitro Study

Author:

Makker Raveena1,Choukse Vivek2,Gupta Shilpi G3,Srivastava Rajeev1,Khandelwal Sourabh1,Reddy Prashanthi4

Affiliation:

1. Department of Prosthodontics, Crown & Bridge, Index Institute of Dental Sciences, Indore, Madhya Pradesh, India

2. Department of Prosthodontics, Crown & Bridge, Dr. Hegdewar Smruti Rugna Seva Mandals Dental College and Hospital, Hingoli, Maharashtra, India

3. Department of Prosthodontics, Crown and Bridge and Implantology, Government College of Dentistry, Indore, Madhya Pradesh, India

4. Department of Oral Medicine and Radiology, Government College of Dentistry, Indore, Madhya Pradesh, India

Abstract

Introduction: Dimensional accuracy when making impressions is crucial to the quality of fixed prosthodontics treatment, and impression materials are critical factors affecting this accuracy. The purpose of the study was to evaluate and compare the dimensional accuracy of resultant casts made by monophase polyether and monophase addition silicone impression materials. Materials and Methods: A stainless steel model containing two complete-veneer, fixed partial denture abutment preparations was fabricated with standardized specifications that served as a control. This was then used to compare the impression materials. Seventy gypsum casts were obtained, 35 from each impression material. All the impressions were made in stainless steel perforated custom tray. A tray space of 2 mm was provided for the impression material. Impressions of the stainless-steel model were made using monophase polyether and monophase addition silicone impression material. The accuracy of the two impression materials was assessed by measuring three dimensions (intra- and interabutment) (10-µm accuracy) on stone casts. One-way analysis of variance and Student’s t-test were used for statistical analysis. Results: No statistically significant differences were observed in the dimensional accuracy of stone dies obtained with both materials as compared to those of the stainless-steel model (p > 0.01). Conclusions: Within the limitations of this study, it was found that there was no significant difference in the dimensional accuracy of resultant casts made by monophase polyether and monophase addition silicone impression materials. However, the dimensional measurements of casts fabricated from monophase addition silicone were found to be closer to control as compared to monophase polyether.

Publisher

Medknow

Reference25 articles.

1. Accuracy of three polyvinyl siloxane putty-wash impression techniques;Nissan;J Prosthet Dent,2000

2. Comparison of elastomeric impression materials used in fixed prosthodontics;Ciesco;J Prosthet Dent,1981

3. Dimensional accuracy of stone casts made by a monophase impression technique using different elastomeric impression materials;Vitti;Braz J Oral Sci,2011

4. Impression materials in fixed prosthodontics: influence of choice on clinical procedure;Hamalian;J Prosthodont,2011

5. A review of contemporary impression materials and techniques;Donovan;Dent Clin N Am,2004