Diagnostic accuracy of indigenously developed computer-based binocular vision assessment

Author:

Kumar P. Praveen,Shajahan T.,Hussaindeen Jameel Rizwana

Abstract

CONTEXT: The increased prevalence of nonstrabismic binocular vision anomalies (NSBVA) has given rise to the need for cost-effective screening and diagnostic tools. AIMS: The aim of the study is to assess the efficacy of an indigenously developed computer-based binocular vision assessment software (Train Your Eyes®) in screening NSBVA. SUBJECTS AND METHODS: Subjects who visited the binocular vision clinic of a tertiary eye care center with asthenopic symptoms between January 2019 and January 2020 were included in the study. Patients with other ocular comorbidities and stereopsis poorer than 500 arc seconds were excluded. All subjects underwent a comprehensive eye examination followed by binocular vision assessment using both the manual and computer-based methods. STATISTICAL ANALYSIS USED: Receiver operating characteristic (ROC) curves were utilized to choose the cut-off points that maximize the sensitivity and specificity. RESULTS: The mean (standard deviation) age of 88 subjects was 22 (4.5) years with 34 males. Based on the conventional manual assessment, 71 (81%) were diagnosed to have NSBVA and 17 (19%) had normal binocular vision. Based on the ROC analysis, the following cut-off points are proposed: 14 prism diopter (PD) for near positive fusional vergence amplitudes, 4.5 PD for near negative fusional vergence amplitudes, 4.5 cycles per minute (cpm) for binocular accommodative facility, and 3.5 cpm for monocular accommodative facility. All the binocular vision parameters demonstrated statistical significance in the ROC analysis (P < 0.05). CONCLUSIONS: The software-based screening tool was found to be highly sensitive in identifying NSBVA and thus could be used as a potential screening tool in the clinic and community.

Publisher

Medknow

Reference15 articles.

1. Prevalence of vision and ocular disease conditions in a clinical pediatric population;Scheiman;J Am Optom Assoc,1996

2. Frequency of convergence insufficiency in optometry clinic settings. Convergence insufficiency and reading study (CIRS) group;Rouse;Optom Vis Sci,1998

3. Prevalence of non-strabismic anomalies of binocular vision in Tamil Nadu: Report 2 of BAND study;Hussaindeen;Clin Exp Optom,2017

4. The minimum test battery to screen for binocular vision anomalies: Report 3 of the BAND study;Hussaindeen;Clin Exp Optom,2018

5. The effect of refractive error and race on the vergence and accommodation systems;Chen;ACBO Behav Optom J,2000

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3