Correlation between retinal nerve fiber layer thickness and anterior segment parameters in patients with pseudoexfoliation: A cross-sectional comparative study

Author:

Rathinam Nithya1,Kasturi Nirupama1,Kaliaperumal Subashini1,Jayaseelan Venkatachalam2

Affiliation:

1. Department of Ophthalmology, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India

2. Department of Preventive and Social Medicine, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India

Abstract

PURPOSE: The purpose of this study was to assess the retinal nerve fiber layer (RNFL) thickness in patients with pseudoexfoliation (PXF) and to correlate it with anterior segment parameters such as intraocular pressure (IOP), central corneal thickness (CCT), pigments in angle structures, and grades of PXF. METHODOLOGY: This was a cross-sectional comparative study in a tertiary care center. Patients having unilateral PXF were categorized as group 1. Age- and sex-matched healthy controls were categorized as group 2. All subjects underwent IOP measurement, CCT measurement, and retinal nerve fiber thickness measurement. Subjects in group 1 also underwent gonioscopy and perimetry. Data were entered and analyzed using the IBM-SPSS program (version 20.0); Chicago, IL. RESULTS: Mean RNFL thickness in group 1 was 85.91 ± 22.237 μ and in group 2 was 106.65 ± 6.1 μ. The mean RNFL thickness in patients with PXF syndrome was 103.38 ± 5.815 μ and in patients with PXF glaucoma was 67.82 ± 17.984 μ. The mean CCT in patients with PXF syndrome was 516.41 ± 23.03 μ and in patients with PXF glaucoma was 507 ± 33.05 μ and control group was 526.6 m. The mean IOP in patients with PXF syndrome was 8 ± 6.01 mmHg; in patients with PXF glaucoma was 17.21 ± 7.33 mmHg; and in the control group was 14.12 ± 2.693 mmHg. There was a negative correlation between IOP and RNFL thickness, and a positive correlation between CCT and RNFL thickness, but it was not statistically significant. A statistically significant correlation was found between grades of PXF and RNFL thinning with a correlation coefficient of 0.437 (P = 0.001). CONCLUSION: Patients with PXF have a lower CCT, higher mean IOP, and RNFL thinning compared to normal subjects. The presence of grade 3 PXF (on the lens surface edge) showed a statistically significant correlation with RNFL thinning.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3