Analysis of Corneal Biomechanical Properties in Different Keratotopographic Patterns of Keratoconus

Author:

Solodkova Elena Gennadievna1,Malyugin Boris Eduardovich2,Zakharov Igor Nikolayevich3,Le Van Hoang3,Balalin Sergey Viktorovich1,Lobanov Evgeniy Valeryevich1,Balalin Alexandr Sergeevich1

Affiliation:

1. Volgograd Branch of S. Fyodorov Eye Microsurgery Federal State Institution, Volgograd, Russia

2. S. Fyodorov Eye Microsurgery Federal State Institution, Moscow, Russia

3. Department of Resistance of Materials, Volgograd State Technical University, Volgograd, Russia

Abstract

Purpose: To analyze the frequency of main keratotopographic patterns at the 1st, 2nd, and 3rd stages of keratoconus and investigate corneal biomechanical properties across different patterns. Methods: The study comprised two stages. The first stage was computational-experimental, where we utilized COMSOL Multiphysics® software (COMSOL AB, Stockholm, Sweden) to mathematically model corneal mechanical behavior under intraocular pressure and pulsed air jet action in both normal and keratoconic conditions. The second stage was the clinical phase, during which we retrospectively analyzed the examination results of both healthy subjects and patients with keratoconus. In total, the study included 256 eyes (256 subjects). Among them, 174 eyes (174 healthy individuals) had normal corneas with different refractions, and 82 eyes (82 individuals) had stages 1, 2, and 3 of keratoconus based on Amsler–Krumeich classification. The keratotopographic characteristics of the participants were assessed using Sirius (Schwind, Germany) and Pentacam AXL (OCULUS Optikgeräte GmbH, Germany) keratotomographs, while the corneal biomechanical properties were studied using noncontact tonometry with the Corvis ST device (OCULUS Optikgeräte GmbH, Germany). The study focused on evaluating corneal stiffness index values in the central optical zone under various keratotopographic patterns. In addition, it compared the elastic coefficient values c 1, c 2, and c 3 for the model of hyperelastic behavior of corneal material outside the keratoconus zone. Furthermore, the study examined the values of reduced stiffness zone characteristics, including the stiffness reduction factor ψmax, effective radius R k, and the ratio of maximum and minimum strain intensity in keratoconus of different stages. Results: The mean age of the patients in the study was 30.16 ± 8.31 years, with 166 men and 90 women participating. The study revealed typical keratotopographic patterns in the examined keratoconus stages, as well as their occurrence frequency. In the 1st stage of keratoconus, the pattern of asymmetric astigmatism was noted more frequently (in 75% of cases). In the 2nd stage, the pattern with an ectasia zone in the lower cornea was observed in 80% of cases, and in the 3rd stage, a centrally located keratotopographic ectasia pattern was found in 42% of cases. Comparative analysis showed that the greatest decrease in stiffness parameter (SpA1) and stress–strain index occurred in the central pattern (by 64% and 46%, respectively), while the least decrease was observed in local corneal radius reduction in the lower cornea (by 42% and 33%, respectively). Conclusions: The decrease in strength properties in keratoconus occurs in a local area, the size and degree of which are determined by the disease stage. The indicated biomechanical parameters are consistent regardless of the shape and localization of keratotopographic patterns but are relevant to diagnostic specifications using the Corvis ST pneumotonometer, which assesses corneal properties in the apical zone.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3