Assessment of the Dosimetric Performance of the Mobius3D against Portal Dose Measurements in Patient-specific Quality Assurance

Author:

Labagnoy Yasmine Joy M.1,Oonsiri Sornjarod2,Vimolnoch Mananchaya2,Kingkaew Sakda2

Affiliation:

1. Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand

2. Department of Radiology, Division of Radiation Oncology, King Chulalongkorn Memorial Hospital, Bangkok, Thailand

Abstract

Aim: The Mobius3D software addresses limitations lacking in measurement-based methods in patient-specific quality assurance (QA). The objective of this study was to validate its dosimetric performance against conventionally used portal dose measurements using gamma analysis and confidence limits. Materials and Methods: A total of 240 patient-specific QA plans for the Varian Halcyon linear accelerator were collected. The Mobius3D software was commissioned through beam data and plan verification. All plans underwent QA through the electronic portal imaging device, coupled with the Portal Dosimetry software, and the Mobius3D. Data were assessed using >95% gamma pass. Portal measurements were evaluated using 3%/2 mm and 3%/3 mm criteria, whereas Mobius3D was analyzed at 3%/3 mm and 5%/3 mm, at the 10% threshold. Results: Mobius 5%/3 mm mean gamma passes were 99.89% for volumetric-modulated arc therapy (VMAT) and 99.31% for intensity-modulated radiotherapy (IMRT), and correspondingly, the data for portal 3%/2 mm were 99.99% and 99.96%. The Mobius3D at 5%/3 mm can perform like Portal 3%/2 mm for VMAT plans at 0.1% difference, especially for head/neck and pelvic/abdominal cases. In IMRT-based treatments, at 0.7% difference in Mobius3D 5%/3 mm and Portal 3%/2 mm, the performance and error identification in IMRT plans should be applied more carefully due to the amount of failed plans, particularly the chest region. The confidence limits for VMAT plans for Portal 3%/2 mm and Mobius 5%/3 mm are 99.93% and 99.42%, respectively, while for IMRT plans are 99.69% and 97.43%, respectively. Conclusions: At a 5%/3 mm criterion, the Mobius3D may yield percentage gamma pass rates like measurements obtained by Portal Dosimetry 3%/3 mm and Portal Dosimetry 3%/2 mm. As the software is largely dependent on commissioned data, rigorous commissioning and a comprehensive QA program should be implemented.

Publisher

Medknow

Subject

Radiology, Nuclear Medicine and imaging,Biophysics

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3