Assessing Heterogeneity Effects on Points A, B, and Organs at Risk Doses in High-dose-Rate Brachytherapy for Cervical Cancer – A Comparison of 192Ir and 60Co Sources Using Monte Carlo N-Particle 5

Author:

Sadeghi Mohammad Hossein1,Sina Sedigheh12,Meigooni Ali Soleimani3

Affiliation:

1. Department of Nuclear Engineering, School of Mechanical Engineering, Shiraz University, Shiraz, Iran

2. Radiation Research Center, School of Mechanical Engineering, Shiraz University, Shiraz, Iran

3. Department of Radiation, Medicine UK Chandler Medical Center, Lexington, KY, USA

Abstract

Purpose: The present article deals with investigating the effects of tissue heterogeneity consideration on the dose distribution of 192Ir and 60Co sources in high-dose-rate brachytherapy (HDR-BT). Materials and Methods: A Monte Carlo N-Particle 5 (MCNP5) code was developed for the simulation of the dose distribution in homogeneous and heterogeneous phantoms for cervical cancer patients. The phantoms represented water-equivalent and human body-equivalent tissues. Treatment data for a patient undergoing HDR-BT with a 192Ir source were used as a reference for validation, and for 60Co, AAPM Task Group 43 methodology was also applied. The dose values were calculated for both source types in the phantoms. Results: The results showed a good agreement between the calculated dose in the homogeneous phantom and the real patient’s treatment data, with a relative difference of less than 5% for both sources. However, when comparing the absorbed doses at critical points such as Point A right, Point A left, Point B right, Point B left, bladder International Commission on Radiation Units and Measurement (ICRU) point, and recto-vaginal ICRU point, the study revealed significant percentage differences (approximately 5.85% to 12.02%) between the homogeneous and heterogeneous setups for both 192Ir and 60Co sources. The analysis of dose–volume histograms (DVH) indicated that organs at risk, notably the rectum and bladder, still received doses within recommended limits. Conclusions: The study concludes that 60Co and 192Ir sources can be effectively used in HDR-BT, provided that careful consideration is given to tissue heterogeneity effects during treatment planning to ensure optimal therapeutic outcomes.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3