The Investigating Image Registration Accuracy and Contour Propagation for Adaptive Radiotherapy Purposes in Line with the Task Group No. 132 Recommendation

Author:

Archawametheekul Kamonchanok1,Puttanawarut Chanon23,Suphaphong Sithiphong1,Jiarpinitnun Chuleeporn1,Sakulsingharoj Siwaporn1,Stansook Nauljun1,Khachonkham Suphalak1

Affiliation:

1. Division of Radiation Oncology, Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand

2. Chakri Naruebodindra Medical Institute, Mahidol University, Samut Prakan, Thailand

3. Department of Clinical Epidemiology and Biostatistics, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand

Abstract

Purpose: Image registration is a crucial component of the adaptive radiotherapy workflow. This study investigates the accuracy of the deformable image registration (DIR) and contour propagation features of SmartAdapt, an application in the Eclipse treatment planning system (TPS) version 16.1. Materials and Methods: The registration accuracy was validated using the Task Group No. 132 (TG-132) virtual phantom, which features contour evaluation and landmark analysis based on the quantitative criteria recommended in the American Association of Physicists in Medicine TG-132 report. The target registration error, Dice similarity coefficient (DSC), and center of mass displacement were used as quantitative validation metrics. The performance of the contour propagation feature was evaluated using clinical datasets (head and neck, pelvis, and chest) and an additional four-dimensional computed tomography (CT) dataset from TG-132. The primary planning and the second CT images were appropriately registered and deformed. The DSC was used to find the volume overlapping between the deformed contours and the radiation oncologist (RO)-drawn contour. The clinical value of the DIR-generated structure was reviewed and scored by an experienced RO to make a qualitative assessment. Results: The registration accuracy fell within the specified tolerances. SmartAdapt exhibited a reasonably propagated contour for the chest and head-and-neck regions, with DSC values of 0.80 for organs at risk. Misregistration is frequently observed in the pelvic region, which is specified as a low-contrast region. However, 78% of structures required no modification or minor modification, demonstrating good agreement between contour comparison and the qualitative analysis. Conclusions: SmartAdapt has adequate efficiency for image registration and contour propagation for adaptive purposes in various anatomical sites. However, there should be concern about its performance in regions with low contrast and small volumes.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3