Feasibility of Four-dimensional Adaptation of Volumetric Modulated Arc Therapy Based on Volumetric Modulated Arc Therapy-computed Tomography

Author:

Zhao Xiaodong1,Zhang Rui23

Affiliation:

1. Department of Radiation Oncology, Washington University in St. Louis, St. Louis, Missouri, USA

2. Department of Physics and Astronomy, Louisiana State University, Baton Rouge, Louisiana, USA

3. Department of Radiation Oncology, Mary Bird Perkins Cancer Center, Baton Rouge, Louisiana, USA

Abstract

Purpose: Volumetric modulated arc therapy (VMAT) has been increasingly used for cancer patients due to the fast delivery and improved dose conformity. Adaptive radiotherapy (ART) can significantly decrease dose to normal tissues and allow for dose escalation. However, current imaging techniques cannot provide four-dimensional (4D) patient anatomy or dose information during VMAT, which is critical for ART that involves respiratory motion. A novel imaging tool named VMAT–computed tomography (VMAT-CT) has the potential to reveal intra-fractional patient information. The goal of this study was to evaluate the feasibility of 4D adaptive VMAT based on 4D VMAT-CT. Materials and Methods: A commercial QUASAR respiratory phantom and an in-house deformable lung phantom were used in this study, and lung VMAT plans, including 4D union plan and 4D ART plan, were generated for the phantoms. A real lung patient’s plan was also used in this feasibility study. ART plans based on 4D VMAT-CT were created for the phantoms and the real patient when planning goals were not met. Dose escalation plan based on 4D VMAT-CT was also created for the real patient. Results: Planning target volume (PTV) coverage for the QUASAR phantom was 85.5% after breathing pattern being changed, and went up to 95% after adaptive re-planning. PTV coverage for the deformable phantom was 93% after deformation and breathing pattern being changed, and went up to 95% after re-planning. Re-planning and dose escalation were feasible and can spare normal tissues for the real patient. 4D ART plan based on 4D VMAT-CT required smaller margins than 4D union plan while maintaining the same prescription dose coverage. Conclusions: ART based on 4D VMAT-CT is feasible and would potentially facilitate re-planning and PTV dose escalation for VMAT patients who have the motion issue.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3