Multivariate Analysis of Effective Dose and Size-Specific Dose Estimates for Thorax and Abdominal Computed Tomography

Author:

Shah Mudasir Ashraf1,Ahmad Mehtab1,Khalid Saifullah1,Qaseem Syed M. Danish1,Siddiqui Shaista1,Talib Sayema1,Rather Sajad Ahmed2,Firdous Arfat3

Affiliation:

1. Department of Radiodiagnosis, Faculty of Medicine, Jawaharlal Nehru Medical College, Aligarh Muslim University, Aligarh, Uttar Pradesh, India

2. Department of Radiological Physics and Bio-Engineering, Sher-i-Kashmir Institute of Medical Sciences, Srinagar, India

3. Department of Physics, Government Degree College, Sumbal, Jammu and Kashmir, India

Abstract

The study aimed to compute the effective dose (E) and size-specific dose estimate (SSDE) of routine adult patients undergoing thorax and abdominal computed tomography (CT) imaging and to present their multivariate analysis. All adult thorax and abdominal CT examinations conducted from March 2022 to June 2022 were prospectively included in this study. The Water Equivalent Diameter (Dw ) and SSDE of all the examinations were computed from CT dose index volume (CTDIvol ) and Dose length product (DLP) displayed on the dose report in the CT console. The multivariate statistical analysis was performed to investigate the correlation of SSDE and E on CTDIvol , Dw area of the region of interest (ROI) (AreaROI ), body mass index (BMI), conversion factor (fsize) and hounsfield (HUmean ) number in the ROI at 95% level of significance (P < 0.05). The linear regression analysis was performed to investigate the dependence of SSDE and E on other parameters for both abdominal and thorax patients. A total number of 135 (Abdomen = 61 and Thorax = 74) measurements were performed. The mean value of effective dose for abdomen and thorax patients was found to be 7.17 ± 3.94 and 4.89 ± 2.16 mSv, respectively. The SSDE was observed to be 13.24 ± 3.61 and 13.04 ± 3.61 mGy for thorax and abdomen respectively. The multivariate analysis suggests that SSDE for abdominal CT is found significantly dependent on CTDIvol , Dw and fsize with P < 0.05 and E is found to be significantly dependent on DLP, AreaROI , Dw and fsize at 95% level of confidence for abdominal CT imaging. SSDE for thorax CT was found significantly dependent on BMI, CTDIvol , HUmean , Dw and fsize at 95% level of confidence. Furthermore, E was observed dependent on DLP at P < 0.05. The linear regression analysis also shows that E is strongly correlated with DLP (r = 1.0) for both thorax and abdominal CT, further the SSDE was observed strongly correlated with CTDIvol with r = 0.79 and r = 0.86 for abdomen and thorax CT respectively. A strong correlation was observed between BMI and for Dw abdominal CT imaging (r = 0.68). The mean value of SSDE for thorax is slightly greater than abdomen. The average value of effective dose for abdomen and thorax measurements was found to be 7.17 ± 3.94 and 4.89 ± 2.16 mSv and , correspondingly. SSDE for both abdomen and thorax CT is significantly dependent on CTDIvol , Dw and fsize at 95% level of confidence. The strong correlation was also observed E on DLP and SSDE on CTDIvol for both Abdomen and Thorax CT. The strong dependence of Dw on BMI (r = 0.68) is due to the excessive fat concentration around the stomach and abdomen.

Publisher

Medknow

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3