Validation of American Association of Physicists in Medicine TG 43 Dosimetry Data in Commercial Treatment Planning System

Author:

Saminathan Sathiyan,Maheshraja K.,Ganesh K. M.

Abstract

Aims This study aimed to validate the dosimetric data of low-energy photon-emitting low-dose rate (LE-LDR) brachytherapy seed sources in commercial treatment planning system (TPS). Materials and Methods The LE-LDR seed sources dosimetric data were published in the American Association of Physicists in Medicine (AAPM) Task Group reports TG-43 (1995), TG-43U1 (2004), TG-43U1S1 (2007), and TG-43U1S2. The Bhabha Atomic Research centre (BARC) 125I Ocu-Prosta seed dosimetry data are also available in the literature. The commercially available TPSs are using both two-dimensional (cylindrically symmetric line-source) and one-dimensional (1D) (point source) dose-calculation formalisms. TPS used in this study uses only 1D dose-calculation formalism for permanent implant dosimetry. The point-dose calculation, dose summation, isodose representation, and dose–volume histogram quality assurance tests were performed in this study. The point-source dose-calculation tests were performed for all the available sources in the literature. The others tests were performed for the I-125 BARC Ocu-Prosta seeds. The TPS-calculated doses were validated using manual calculation. Results and Discussion In point-source calculation test, the TPS-calculated point-dose values are within ±2% agreement with manually calculated dose for all the seeds studied. The agreement between the TPS and manually calculated dose is 0.5% for the dose summation test. The isodose line pass through the grid points at an equal distance was verified visually on the computer screen for seed used clinically. In dose–volume histogram test, the TPS-determined volume was compared with the real volume. Conclusion Misinterpretation of the TPS test and/or misunderstanding of the TG-43 dose-calculation formalism may cause large errors. It is very important to validate the TPS using literature provided dosimetric data. The dosimetric data of BARC 125I Ocu-Prosta Seed are validated with other AAPM TG-43-recommended seeds. The dose calculation of Best® NOMOS permanent implant TPS is accurate for all permanent implant seeds studied.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3