Application of a Comprehensive Treatment Planning Test for Credentialing Intensity-Modulated Radiotherapy and RapidArc in a TrueBeam Linear Accelerator Setup

Author:

Roy Soumya12,Sarkar Biplab23,Pradhan Anirudh4

Affiliation:

1. Department of Radiation Oncology, Manipal Hospital, New Delhi, India

2. Departments of Physics, GLA University, Mathura, Uttar Pradesh, India

3. Radiation Oncology, Apollo Multispeciality Hospital, Kolkata, West Bengal, India

4. Centre for Cosmology, Astrophysics and Space Science (CCASS), GLA University, Mathura, Uttar Pradesh, India

Abstract

An extended version of task group report (TG)-119 dosimetric tests was introduced and tested on the TrueBeam linear accelerator setup. Treatment plan results and quality assurance (QA) results of RapidArc (RA) and intensity-modulated radiotherapy (IMRT) were compared to understand the limitation and efficacy of the RA and IMRT system of the linear accelerator. Test structure sets were drawn on OCTAVIUS four-dimensional (4D) phantom computed tomography scan data for this study. We generated treatment plans based on the specified goal in the Eclipse™ treatment planning system using RA and IMRT in the study phantom. We used the same planning objectives for RA and IMRT techniques. Planar dose verification was performed using electronic portal imaging device and OCTAVIUS 4D phantom. The treatment log file was further analyzed using Pylinac (V2.4.0 (Open Source Code library available on Github, runs under Python programming language)) to compare the dosimetric outcome of RA and IMRT. Dose to the planning target volume (PTV) 1–5 and organ at risk (OAR) were analyzed in this study for the efficiency comparison of RA and IMRT. The primary objective was accomplished by adhering to the dose constraints associated with PTV 2 and the OAR. RA and IMRT also met the secondary objective. The tertiary goal of dose delivery to PTV 4 was met with RA but not IMRT. This study can be utilized to compare different institutions’ planning and patient-specific QA (PSQA) procedures. The findings of this study were in line with the published works of the literature. A multi-institutional planning and delivery accuracy audit can be built using this structure and set of planning objectives having similar PSQA phantom. The TG-119 report incorporated test challenges that were combined in a single study set and a single plan. This reduces the complexity of performing the original TG-119 tests, whereas keeping the challenges as introduced in the TG-119 report. This study’s planning and dosimetric results could be further utilized for dosimetry audit with any institute having a linear accelerator and OCTAVIUS 4D phantom for PSQA.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3