Assessing the surgical competency of novice surgeons by using a three-dimensional heads-up display microscope

Author:

Varman Aadithreya1,Varman N V Arulmozhi2,Balakumar Dinesh3

Affiliation:

1. Director, Uma Eye Clinic, Chennai, Tamil Nadu, India

2. Chairman, Uma Eye Clinic, Chennai, Tamil Nadu, India

3. Department of Cataract and Refractive Surgery, Uma Eye Clinic, Chennai, Tamil Nadu, India

Abstract

Purpose: To evaluate the surgical performance of novice surgeons operating on a three-dimensional (3D) heads-up display system compared to those using a traditional microscope (TM). Methods: Prospective study design in a private practice setting. Twenty novice surgeons with similar experiences in cataract surgery were selected. Each surgeon performed 20 phacoemulsification cataract surgeries: 10 surgeries on the 3D heads-up display microscope, and 10 surgeries using a TM system. Data were collected from a total of 400 patients operated on by 20 surgeons. Outcome measures were recorded and graded according to the International Council of Ophthalmology’s Ophthalmology Surgical Competency Assessment Rubric-Phacoemulsification system. The main outcome measure was mean surgical competency scores. Results: Overall, 400 data points were equally distributed between TM (200) and 3D (200) surgeries. The mean surgical competency scores were 60.19 (11.41) for TM surgeries and 62.99 (11.11) for 3D surgeries. 3D surgeries had significantly higher surgical competency scores than TM surgeries (P = 0.013). The mean surgical duration for TM and 3D surgeries was 35.98 (6.02) min and 34.31 (7.12) min, respectively. 3D surgeries took significantly less time than TM surgeries (P = 0.012). The overall mean best corrected visual acuity in the logarithm of the minimum angle of resolution units was 0.27 (0.42); in TM and 3D surgeries, it was 0.28 (0.43) units and 0.26 (0.41) units, respectively. Conclusion: The 3D heads-up display system enhances stereopsis in cataract surgery, making it a valuable training tool for novice surgeons in phacoemulsification procedures.

Publisher

Medknow

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3