Biomechanical properties of cornea and ocular aberrations in myopic eyes

Author:

Dhiman Rebika1,Singh Divya1,Vanathi Murugesan1,Tandon Radhika1,Mahalingam Karthikeyan1

Affiliation:

1. Dr. R. P. Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India

Abstract

Abstract Purpose: To study the correlation of corneal topography, corneal biomechanical properties, and ocular aberrations with the magnitude of refractive error in myopic eyes. Methods: All myopic patients attending the clinic for refractive surgery were recruited. Data recorded included visual acuity, axial length (AL), central corneal thickness (CCT), manifest refraction spherical equivalent (MRSE), topography (Pentacam – Oculus), corneal biomechanical factors [ocular response analyzer (ORA)], and optical aberrations (iTrace). They were further categorized into group 1 (suitable for femto-LASIK) and group 2 (unsuitable for femto-LASIK). Results: Sixty eyes (30 myopes) of mean age 22.78 ± 2.71 years were enrolled. A negative correlation of refractive error was noted with AL (ρ = −0.9; P < 0.001), total aberrations (ρ = 0.53; P < 0.001), and lower-order aberrations (LOA) (ρ = 0.54; P < 0.001). A strongly positive correlation was noted between CCT and corneal hysteresis (CH) (ρ = 0.63; P < 0.001), CCT and CRF (ρ = 0.56; P < 0.001), CH and corneal resistance factor (CRF) (ρ = 0.83; P < 0.001), and Goldmann equivalent intraocular pressure (IOPg) and corneal compensated intraocular pressure (IOPcc) (ρ = 0.78; P < 0.001). An increase in higher-order aberrations (HOAs) as well as lower-order aberrations (LOAs) was noted with increasing sim-K [HOA (r = 0.73, P = 0.001); LOA (r = 0.601, P = 0.014)] and increasing CRF [HOA (r = 0.5, P = 0.006); LOA (r = 0.732, P = 0.001)] in group 2. The amount of refractive error, axial length, central corneal thickness, and sim-K were significantly different in the two groups. Conclusion: Increasing degree of myopia is associated with an increase in axial length, total aberrations, and lower-order aberrations. Corneal biomechanical parameters have a strong correlation with each other. Lower corneal biomechanics are noted in high myopes as they have weaker and thinner corneas. Corneal biomechanics and ocular aberrations do not differ significantly between cases suitable for femto-LASIK and cases unsuitable for femto-LASIK.

Publisher

Medknow

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3