High-sensitivity Troponin I Assay for Early Detection of Myocardial Injury in Carbon Monoxide Intoxication

Author:

Tsai Tsung-Neng12,Shen Chih-Hao3,Lin Gen-Min45,Liu Pang-Yen16,Liu Ming-Yueh78,Huang Li-Yen129

Affiliation:

1. Department of Internal Medicine, Division of Cardiology, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan

2. Department of Clinical Medicine, Graduate Institute of Medical Sciences, National Defense Medical Center, Taipei, Taiwan

3. Department of Internal Medicine, Division of Pulmonary and Critical Care, Hyperbaric Oxygen Therapy Center, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan

4. Department of Internal Medicine, Hualien Armed Forces General Hospital, Hualien, Taiwan

5. Department of Internal Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan

6. Department of Cardiovascular Medicine, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan

7. Department of Radiation Oncology, Taichung Armed Forces General Hospital, Taichung, Taiwan

8. Department of Radiation Oncology, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan

9. Department of Internal Medicine, Division of Cardiology, Armed Forces Taoyuan General Hospital, Taoyuan, Taiwan

Abstract

Abstract Background: Carbon monoxide (CO) intoxication is the most common gas-related event resulting in emergency room (ER) visits, often leading to myocardial injuries measured through the assessment of troponin levels. Recent efforts have focused on developing high-sensitivity troponin assays for more accurate acute myocardial infarction diagnosis. However, studies using high-sensitivity troponin I (hs-TnI) assays to identify myocardial injury following CO intoxication are lacking. Aim: We compared the measurement of circulating troponin I levels using the hs-TnI assay and the contemporary troponin I (cTnI) assay. Materials and Methods: We prospectively analyzed 50 patients with CO intoxication who were admitted to the ER between September 2012 and October 2013. Clinical, demographic, electrocardiographic (ECG), echocardiographic, and laboratory data were compared. Circulating troponin I levels were measured using hs-TnI and cTnI assays upon arrival in the ER and 24, 48, and 72 h after admission. Results: Most patients with moderate or severe CO intoxication had elevated circulating troponin I levels, as detected using the hs-TnI assay. In addition, none of the results above or below the cutoff value for circulating troponin I changed from those found in the ER. In the cTnI assay, elevated circulating troponin I above the cutoff value in the ER was detected in 21 of 36 patients (58%). Participants with elevated troponin I levels, as measured by the hs-TnI assay, were more likely to experience various unfavorable clinical outcomes. Conclusion: The hs-TnI assay can detect elevated circulating troponin I levels earlier than the cTnI assay in patients with CO intoxication and myocardial injury.

Publisher

Medknow

Reference26 articles.

1. Clinical practice. Carbon monoxide poisoning;Weaver;N Engl J Med,2009

2. Myocardial injury in carbon monoxide poisoning;Rastelli;G Ital Cardiol (Rome),2009

3. Carbon monoxide intoxication:An updated review;Prockop;J Neurol Sci,2007

4. Acute myocardial infarction;Anderson;N Engl J Med,2017

5. High-sensitivity troponin T versus I in acute coronary syndrome:Prediction of significant coronary lesions and long-term prognosis;Kvisvik;Clin Chem,2017

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3