Comparison of diagnostic performance between diffusion models parameters and mono-exponential apparent diffusion coefficient in patients with prostate cancer: A systematic review and meta-analysis

Author:

Nematollahi Hamide1,Maracy Mohammad Reza2,Moslehi Masoud1,Shahbazi-Gahrouei Daryoush1

Affiliation:

1. Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran

2. Department of Epidemiology and Biostatistics, School of Public Health, Isfahan University of Medical Sciences, Isfahan, Iran

Abstract

Background: The importance of diffusion in prostate cancer (PCa) diagnosis has been widely proven. Several studies investigated diffusion models in PCa diagnosis. Materials and Methods: This systematic review and meta-analysis study was performed to evaluate the ability of three diffusion models to diagnose PCa from the scientific electronic databases Embase, PubMed, Scopus, and Web of Science (ISI) for the period up to March 2022 to identify all relevant articles. Results: Eighteen studies were included in the systematic review section (7 diffusion kurtosis imaging [DKI] studies, 4 diffusion tensor imaging [DTI] studies, 4 intravoxel incoherent motion [IVIM] studies, and 3 IVIM-DKI studies). Pooled sensitivity, specificity, accuracy, and summary area under each diffusion model’s curve (AUC) and 95% confidence intervals (CIs) were calculated. The pooled accuracy and 95% CI on detection (differentiation of tumor from normal tissue and benign prostatic hyperplasia/prostatitis) were obtained for apparent diffusion coefficient (ADC) at 87.97% (84.56%–91.38%) for DKI parameters (Gaussian diffusion [DK] 87.94% [78.71%–97.16%] and deviation from Gaussian diffusion [K] 86.84% [81.83%–91.85%]) and IVIM parameters (true molecular diffusion [DIVIM] 81.73% [72.54%–90.91%], perfusion-related diffusion [D*] 65% [48.47%–81.53%] and perfusion fraction [f] 80.36% [64.23%–96.48%]). The AUC values and 95% CI in the detection of PCa were obtained for ADC at 0.95 (0.92–0.97), for DKI parameters (DK 0.94 [0.89–0.99] and K 0.93 [0.90–0.96]) and for IVIM parameters (DIVIM 0.85 [0.80–0.91], D* 0.60 [0.43–0.77] and f 0.73 [0.63–0.84]). Two studies showed that the DTI accuracy values were 97.34% and 85%. For IVIM–kurtosis model in PCa detection, two studies stated that the DIVIM-K and KIVIM-K accuracy values were 85% and 84.44% (the pooled accuracy; 84.64% with 95% CI 75.78%–93.50%), and 72.50% and 71.11% (the pooled accuracy, 72.10% with 95% CI 64.73%–79.48%), respectively. Conclusion: Our findings showed that among the DKI, IVIM, and ADC parameters, it seems that ADC, Dk, DIVIM, and K are the most important, which can be used as an indicator to distinguish PCa from normal tissue. The DKI model probably has a higher ability to detect PCa from normal tissue than the IVIM model. DKI probably has the same diagnostic performance in PCa detection and grading compared to diffusion-weighted imaging and ADC.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3