Comparison of optical low coherence interferometry and Scheimpflug imaging combined with partial coherence interferometry biometers in cataract eyes

Author:

Kim Moonjung,Han Eui S.

Abstract

PURPOSE: The purpose of the study was to evaluate the agreement between measurements by optical low-coherence interferometry (OLCI, Aladdin) and those by Scheimpflug imaging combined with partial coherence interferometry (Scheimpflug-PCI, Pentacam AXL) in cataract patients. METHODS: This was a retrospective comparative study conducted in the United Arab Emirates. Axial length (AL), corneal power (keratometry, K), anterior chamber depth (ACD), and corneal astigmatism in patients with cataracts were measured with both devices. Difference and correlation were evaluated with paired t-test (p) and Pearson's correlation coefficient®, respectively. RESULTS: A total of 164 eyes of 95 patients were analyzed (164 eyes for K, 155 for ACD, and 112 for AL). The mean AL taken by OLCI was longer than that by Scheimpflug-PCI (23.25 mm vs. 23.23 mm, P ≤ 0.0001), showing an excellent correlation between the two (r = 0.9990). ACD measured by OLCI was 0.08 mm shallower than that by Scheimpflug-PCI (P = 0.0003, r = 0.7386). Corneal power measured by OLCI was lower than that by Scheimpflug-PCI (differences in mean K, flat K, and steep K were 0.05 diopters (D), 0.08 D, and 0.02 D, respectively), showing very strong correlations between the two devices (r = 0.9614, 0.9445, and 0.9535, respectively). Only flat K values measured with the two devices were significantly different (P = 0.0428). There were no statistically significant differences in the magnitude of astigmatism or J45 vector between the two devices (P = 0.1441 and P = 0.4147, respectively). However, J0 vector values were significantly different (P = 0.0087). CONCLUSION: Although OCLI and Scheimpflug-PCI showed strong correlations for measurements of AL, K, ACD, and corneal astigmatism in cataract patients, there were small but statistically significant differences in AL, ACD, flat K, and J0 vector. Thus, these two devices are not interchangeable for calculating intraocular lens power.

Publisher

Medknow

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3