Comparison of optical biometry versus ultrasound biometry in different axial length groups

Author:

Masoud Khorrami-Nejad1,Farshid Babapour Mofrad2,Mahsa Ranjbar-Pazooki2,Heirani Mohsen1,Khodaparast Mehdi1,Yousefi Reza1

Affiliation:

1. Translational Ophthalmology Research Center, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran

2. Department of Medical Radiation Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran

Abstract

Abstract: PURPOSE: The accuracy of optical biometry is higher than ocular ultrasound, but it is expensive and has limitations in patients with dense cataracts. On the other hand, ocular ultrasound biometry is still a frequently used technique in most developing countries due to its lower cost. Therefore, it could be helpful for practitioners to know the interchangeability of optical biometry devices with ultrasound biometry devices. This study is conducted to compare the axial length (AL), anterior chamber depth (ACD), and lens thickness (LT) measured by ocular optical and ultrasound biometers in different AL groups. METHODS: This prospective consecutive study was performed on 248 eyes of 248 patients. Ocular optical biometry was performed using IOLMaster 700 (swept-source optical coherence tomography-based optical biometry, Carl Zeiss, Germany), and the contact ultrasound biometry was carried out using the US-4000 Nidek Echoscan (Gamagori, Japan). Based on measured AL, patients were divided into three groups: the short eye (AL ≤22 mm), normal eye (22 < AL <24.5 mm), and long eye (AL ≥24.50 mm). RESULTS: The agreement of AL between these biometers in all, short, normal, and long eyes was 99.9%, 98.3%, 99.6%, and 99.9%, respectively. The ACD agreement between two devices in all, short, normal, and long eyes was 97.0%, 93.8%, 97.2%, and 96.1%, respectively. Furthermore, the agreement of LT between these biometers in all, short, normal, and long eyes was 74.4%, 89.2%, 66.9%, and 90.7%, respectively. There were a very strong positive correlation in AL (r = 0.999) and ACD (r = 0.947) and a good correlation in LT (r = 0.675) between these devices (all P < 0.001). CONCLUSION: AL and ACD measured by the IOLMaster 700 optical biometer can be used interchangeably with the US-4000 ultrasound biometer in different AL groups. However, LT measured by these biometers cannot be used interchangeably.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3