Abstract

Introduction: Two-dimensional (2D) strain assessment is an important diagnostic and prognostic tool in various clinical conditions, particularly coronary artery disease (CAD). However, these measurements are limited in that the information is obtained in only a single plane (2D). Three-dimensional (3D) strain tracks the myocardium in all 3D, potentially overcoming the limitation of 2D strain. The objective of this study was to establish normal values for 3D strain in a population of healthy, normal controls and to compare these values with 2D strain values. In addition, we sought to evaluate the utility of 3D strain in patients with known or suspected CAD. Methods: We conducted a prospective study at a single major tertiary care center. Individuals were recruited for the study and divided into two groups: a normal control group and a CAD group. Global longitudinal strain (GLS) and global circumferential and global radial strain were calculated by both 2D and 3D strain methods. In addition, 3D was used to calculate area strain. Results: We enrolled a total of 43 individuals (20 normal control group, mean age 33 ± 2.7 years, and 23 CAD group, mean age 57 ± 2.8 years, 80% male). Values for 3D strain were consistently lower for GLS and global circumferential strain in both groups compared with 2D measurements. In the control group, the mean 2D GLS was −20 ± 1.6% versus −17.5 ± 1.5% for 3D GLS (P < 0.001). Similarly, the mean 2D circumferential strain was −17.7 ± 2.3% versus −15.6 ± 2.1% for 3D circumferential strain (P < 0.001). Combining both groups, the sensitivity of GLS for CAD was 80% for 2D versus 93% for 3D. Similar findings were seen for global circumferential strain (sensitivity 87% for 2D vs. 100% for 3D). However, the sensitivity of 3D global radial strain was lower (93% for 2D vs. 47% for 3D). 3D strain data were acquired in a shorter time span compared with 2D (2.2 ± 1 min vs. 3 ± 1 min). Conclusions: 3D strain assessment of longitudinal and circumferential strain is similar but mildly reduced compared with 2D techniques, with similar sensitivity for CAD. Radial strain measurements by 3D, however, are not accurate and correlate poorly with 2D.

Publisher

Medknow

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3