Diagnostic Contribution of Additional Sequences to the Evaluation of Cord Lesions in Patients with Cervical Spinal Multiple Sclerosis in Turkey: A Retrospective Study

Author:

Yagdiran B1,Cakir BT2,Cetin H3

Affiliation:

1. Department of Radiology, Başkent University, Faculty of Medicine, Fevzi Çakmak Cd. 10. Sk. No: 45 Bahçelievler/ANKARA, Turkey

2. Department of Radiology, Gülhane Training and Research Hospital, General Dr. Tevfik Sağlam Cd. No: 1 Etlik/Ankara, Turkey

3. Department of Radiology, Yildirim Beyazit University, Üniversiteler Mahallesi Bilkent Caddesi No: 1, Çankaya, Ankara, Turkey

Abstract

ABSTRACT Background: Multiple Sclerosis (MS) is the most common cause of non-traumatic disability in young adults. Spinal cord involvement is observed in 55-75% of patients with MS. Aim: To identify the strengths and shortcomings of sagittal phase-sensitive inversion recovery (PSIR), sagittal proton density/T2-weighted (PD/T2W), and axial turbo inversion recovery magnitude (TIRM) sequences in the detection of cervical MS plaques by comparing with routine sequences (axial and sagittal T2W, sagittal T1W, sagittal TIRM, fat-suppressed contrast T1W) and therefore determine their diagnostic contributions. Materials and Methods: A total of 48 patients in whom additional magnetic resonance imaging (MRI) sequences were obtained for the diagnosis of cervical MS were retrospectively identified and included in the study. A total of 111 MS plaques were analyzed in terms of visibility, number, size, border sharpness, and intensity ratio based on the routine and additional MRI sequences. The evaluation of the images was independently undertaken by two radiologists. Results: The highest visibility was provided by sagittal PSIR, sagittal TIRM, and axial TIRM sequences (P < 0.05 for all additional sequences). Seven lesions in PD/T2W and four lesions in axial T2W sequences were unable to be detected. Lesions seen in sagittal and axial TIRM sequences were larger than the others. The sharpest borders were determined in the axial TIRM sequence, and the most diffuse borders in the PD/T2W sequence. In intensity ratio, the sagittal PSIR sequence revealed the most significant contrast difference. Conclusion: The sagittal PSIR sequence may improve the detection of cervical MS plaques due to the improved visibility and intensity ratios. The axial TIRM sequence may be more useful than routine axial T2W in the evaluation of visibility, border sharpness, and size measurement of MS plaques.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3