Changes in carotid corrected flow time in guiding fluid resuscitation in septic patients

Author:

Sabri Sherif,Abdelbasset Ahmed,Yassien Ahmed,Nashaat Ahmed

Abstract

Introduction Accurate estimation of intravascular volume status is important in the resuscitation of patients in ICUs. Although intensive fluid therapy in patients with life-threatening volume depletion can prevent death and end-organ damage, volume overload is known to result in increased mortality, morbidity, and duration of hospital stay. Ultrasonography has become a common diagnostic choice in assessment of fluid status in septic patients. This method is noninvasive, easy to learn, and provides real-time assessment at the patient’s bedside. Various ultrasound modalities have been developed to provide accurate and minimally invasive assessment of volume status. In this regard, one of the most promising methods is the evaluation of the blood flow velocity waveform in the descending thoracic aorta via a nonimaging Doppler probe. This modality is based on calculating the systolic flow time with cycle time correction [corrected flow time (FTc)]. FTc is known to be directly associated with volume status. FTc measurement in carotid artery is a completely noninvasive and much more feasible approach. Aim To compare the use of ultrasonography in the measurement of the changes in carotid FTc with echocardiography in the assessment of changes in heart dynamics to assess changes in volume status before and after passive leg raising (PLR) in septic patients. Patients and methods A total of 40 septic patients, including 18 (45.5%) patients as fluid responders and 22 (54.5%) patients as nonfluid responders, were included. Increased FTc by 7 ms, as well as 10% increase in stroke volume was considered to be fluid responsive. Results Our study results showed that 45.5% (n=18) of study population were fluid responders. The PLR test could assess fluid responsiveness with a specificity of 100% and sensitivity of 95% at a cutoff of 10.6% change in CO to predict fluid responsiveness. The study showed a statistically significant moderate positive correlation between CCA FTc and the percent of change in CO measured by echocardiography. An agreement analysis was formed. We concluded that there was a strong relation between change in carotid corrected blood flow and change in COP before and after PLR, with P value less than 0.001. Therefore, we can use this parameter to predict fluid responsiveness after PLR. Conclusions Carotid artery blood flow is a promising noninvasive and easy-to-perform tool for the evaluation of fluid responsiveness in critically ill septic patients. The PLR maneuver has demonstrated excellent performance for predicting fluid responsiveness. It is simple to perform but requires a reliable system of carotid corrected blood flow (COP) monitoring able to quantify the short-term changes.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3