Comparative clinical evaluation of the stability of implants using double acid etching treatment with and without the addition of fluoride solution: A randomized clinical trial

Author:

Hoppe Fernando Luiz Kaesemodel1,Formiga Márcio de Carvalho2,Garcia Gislaine Fernandes Felipe3,Manfro Rafael4,Bortoluzzi Marcelo Carlos5

Affiliation:

1. Department of Oral Implantology, IPENO, Florianopolis, Brazil

2. Department of Periodontology and Oral Implantology, Univali, São José, Brazil

3. Department of Periodontology and Oral Surgery, Unisul, Palhoça, Brazil

4. Department of Oral Surgery, UNOESC, Joaçaba, SC, Brazil

5. Department of Dentistry, State University of Ponta Grossa, Av. Carlos Cavalcanti, Ponta Grossa, PR, Brazil

Abstract

Abstract Background: Osseointegration depends on primary stability, and further, implant surface modifications may improve secondary stability. This randomized clinical trial evaluates whether adding a fluoride solution enhances the implant stability. Materials and Methods: Stability of dental implants with two different types of surface treatments was compared utilizing resonance frequency analysis (RFA). Twelve patients were recruited: eight females and four males with an average age of 58.3 years and they received either double acid etched implants (control: Porus Implant, Sistema Conexão) and double acid etched implants containing fluoride on their surfaces (test: Porus Nano Implant, Sistema Conexão). Each patient received one implant from the test category and another implant from the control category, resulting in 24 implants in this study. RFA, utilizing Osstell was used to assess the implant stability, immediately after the placement of implant and 15, 30 and 45 days post-implant placement. Results: At the initial time, there was no difference between the test and control groups regarding the ISQ. However, after 15, 30, and 45 days, ISQ values for the test group were significantly higher than the control group. When using implants without fluoride addition, it was observed that after 15 days, the ISQ values were lower than those found at the initial time, but after 30 days, values matched the initial. Concerning the test group results, the ISQ values from T0 (immediately after implant placement) to T3 (45 days after implant placement) always increased from every period of evaluation. Conclusions: It was concluded that double acid etched implants with surfaces containing fluoride solution increases the implant stability quotient, compared to implants with fluoride-free double acid etched surfaces.

Publisher

Medknow

Reference32 articles.

1. Methods used to assess implant stability:Current status;Atsumi;Int J Oral Maxillofac Implants,2007

2. Comparison between bioactive fluoride modified and bionert anodically oxidized implant surfaces in early bone responses using rabit tibia model;Choi;Implant Dent,2012

3. Deposition of nanometer scaled calcium-phosphate crystals to implants with a dual acid-etched surface does not improve early tissue integration;Abrahamsson;Clin Oral Implants Res,2013

4. Osseointegrated titanium fixtures in the treatment of edentulousness;Brånemark;Biomaterials,1983

5. Removal torques for polished and rough titanium implants;Carlsson;Int J Oral Maxillofac Implants,1988

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3