Purpose The aim of this study was to evaluate the accuracy of tumor height measurements with variable probe positions in relation to the center of the spherical shaped globe. Patients and methods This is a retrospective study that included 27 eyes of 27 patients with different types of intraocular tumors recruited from the Ocular Oncology Service at Kasr Alainy Hospitals, Cairo, Egypt. All patients were evaluated by ocular ultrasound using a 20 MHz B scan transducer. Frames of each tumor measurements were evaluated and reassessed to get three heights (in the same visit) at three different positions: H-1: perpendicular with the tumor at central of the scan, H-2: perpendicular with the tumor oblique to the scan, and H-3: oblique with the tumor oblique to the scan. Results Different types of intraocular tumors were evaluated, with choroidal melanomas being the most common (44.4%). The median measurement in H-1 was 4.76±1.89 mm (range=1.82–8.73 mm), while the median measurement in H-2 was 4.94±1.93 mm (range=1.96–8.40 mm), and that in H-3 was 4.93±2.00 mm (range=1.99–8.73 mm). There were no statistically significant differences either between H-1 and H-2 (P=0.92) or between H-1 and H-3 measurements (P=0.97). To evaluate if the tumor height measurements were affected by the tumor size, the lesions were categorized into three groups: small-sized (tumors up to 4.0 mm), medium-sized (tumors from 4.1 to 7.0 mm), and large-sized (tumors >7.0 mm) in height. The large tumors (4/27=15%) showed differences in height measurements according to the positions of the calibers. Conclusion There was no statistically significant evidence on the effect of angulation on tumor height measurement using the 20 MHz B scan combined with vector A scan. However, large tumors should be more accurately calculated by the conventional perpendicular height (H-1) to avoid any error.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3