Three-dimensional/four-dimensional spatiotemporal image correlation morphology of the ductus arteriosus in fetuses with pulmonary atresia undergoing neonatal ductal stenting

Author:

Karapurkar Sonia1,Gurav Aishwarya1,Sudhakar Abish1,Sasikumar Navaneetha1,Kumar Raman Krishna1,Vaidyanathan Balu1

Affiliation:

1. Department of Pediatric Cardiology, Fetal Cardiology Division, Amrita Institute of Medical Sciences, Amrita University, Kochi, Kerala, India

Abstract

ABSTRACT Background: The value of prenatal identification of morphology of ductus arteriosus in fetuses with congenital heart defects (CHD) with pulmonary atresia and duct-dependent pulmonary circulation (DDPC) in planning neonatal ductal stenting procedure is untested. The aim of the study is to analyze the utility of three-dimensional/four-dimensional (3D/4D) spatiotemporal image correlation (STIC) fetal echocardiography in delineating the morphology of ductus arteriosus in fetuses with DDPC undergoing neonatal ductal stenting. Methods: In this retrospective study (2017–22), prenatal imaging of pulmonary artery (PA) anatomy, aortic arch sidedness, and morphology of ductus arteriosus (ductal origin was classified as vertical/horizontal and ductal course as tortuous/straight) was done using 3D/4D STIC imaging and volume datasets. Prenatal findings were correlated with angiographic findings during stenting and the degree of agreement was calculated. Results: We included 27 fetuses with a prenatal diagnosis of CHD with DDPC who underwent neonatal ductal stenting. The accuracy of prenatal assessment of PA anatomy, branch PA stenosis, and arch sidedness was 100%, 92.6%, and 88.9%, respectively. The accuracy of prenatal assessment of ductal origin and course, compared with angiography, was 85.2% and 88.9%, respectively. Prenatal imaging had a diagnostic accuracy of 100% for vertical straight and horizontal tortuous ducts, 84.6% for vertical tortuous, and 67% for horizontal straight ducts. Duct stenting was successful in 25 (92.6%) babies; two died after the procedure from stent occlusion. Conclusion: Fetal echocardiography using 3D/4D STIC imaging enables accurate delineation of the morphology of ductus arteriosus in fetuses with DDPC, thereby aiding parental counseling and planning neonatal ductal stenting.

Publisher

Medknow

Reference25 articles.

1. Detection of critical congenital heart defects:Review of contributions from prenatal and newborn screening;Olney;Semin Perinatol,2015

2. Critical congenital heart disease in newborn:Early detection, diagnosis, and management;Willim;Biosci Med J Biomed Transl Res,2020

3. Mortality for critical congenital heart diseases and associated risk factors in newborns. A cohort study;Lopes;Arq Bras Cardiol,2018

4. Comparison between patent ductus arteriosus stent and modified blalock-taussig shunt as palliation for infants with ductal-dependent pulmonary blood flow:Insights from the congenital catheterization research collaborative;Glatz;Circulation,2018

5. Duct stenting versus modified blalock-taussig shunt in neonates and infants with duct-dependent pulmonary blood flow:A systematic review and meta-analysis;Alsagheir;J Thorac Cardiovasc Surg,2021

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Advances in Diagnosis and Management of Fetal Heart Disease;Current Pediatrics Reports;2024-06-29

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3