Abstract

ABSTRACT Introduction: The study aims to assess the procedural outcomes and follow-up after transcatheter closure of ventricular septal defects (VSDs) in children utilizing the Konar-MF™ occluder (Lifetech Scientific, Shenzhen, PRC) device. Materials and Methods: Clinical features, demographic characteristics, and follow-up findings of children undergoing percutaneous VSD device closure were retrospectively analyzed from the medical records. Results: Fifty-seven patients underwent VSD closure using the Konar-MF occluder between January 2019 and April 2023. Median age and body weight of patients were 36 (5–216) months and 12.5 (3.8–42) kg, respectively. The mean size of the defect on the left ventricular side was 6.5 ± 2.4 mm on echocardiography; the mean pulmonary artery pressure was 19.1 ± 9.7 mmHg. Three patients with severe pulmonary hypertension had successful device closure. The most used device size was 8 mm × 6 mm. The initially chosen device was upsized in 4 (7.01%) patients and downsized in 1 (1.7%) patient. Forty-five patients (78.9%) had device closure through the retrograde route. The procedure was successful in 53 (93.0%) patients. Immediate shunt occlusion was achieved in 86.8% of patients. Major complications, namely, embolization (1) and moderate aortic regurgitation (1) in two patients were successfully managed by surgery. One patient with severe tricuspid regurgitation has been on close follow-up. There was no mortality. Late complications such as valve regurgitation or rhythm disturbance were not identified on a median follow-up of 6 (1.5–47) months. Conclusion: Transcatheter VSD closure using a Konar-MF occluder device is safe and effective, even in smaller children. The ability to deliver both anterogradely and retrogradely is a unique advantage.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3