Topography and Choroidal Thickness Measurement in Healthy Asian Indian Subjects using RTVue XR 100 Optical Coherence Tomography

Author:

Mansoori Tarannum1,Charan Aknoor S. R.2,Nagalla Balakrishna3

Affiliation:

1. Department of Glaucoma, Anand Eye Institute, Hyderabad, Telangana, India

2. Department of Retina, Anand Eye Institute, Hyderabad, Telangana, India

3. Department of Statistics, Apollo Institute of Medical Sciences and Research, Hyderabad, Telangana, India

Abstract

Abstract: PURPOSE: The purpose was to study the choroidal thickness and its profile, derived from different point locations in healthy Asian Indian subjects using RTVue XR 100 optical coherence tomography (OCT) and to determine its correlation with age, refractive error, and axial length. METHODS: In this cross-sectional study, 300 eyes of 150 healthy subjects, with no ocular pathology, were scanned in a single session, using a line scan protocol of RTVue XR 100 OCT. Choroidal thickness was measured at the subfoveal region, and six measurements were obtained on either side of the fovea (temporal and nasal) at 500 μm interval apart, up to 3000 μm. The correlation between subfoveal choroidal thickness and age, refractive error, and axial length was assessed. RESULTS: Three hundred eyes of 150 healthy subjects were included in the analysis. Median age of the study participants was 55 years (interquartile range [IQR]: 44–61). The median subfoveal choroidal thickness was 235 μm (IQR: 210–263). The choroidal thickness was minimum at nasal 3000 μm from the fovea, while it was maximum in the subfoveal region. The point zones which were near the fovea showed thicker choroidal thickness than the outer zones, both nasally and temporally (P < 0.00001 at all locations), and at all point locations the choroid were thicker temporally than nasally (All P < 0.00001). Subfoveal choroidal thickness showed negative correlation with age (coefficient = −0.62, P = 0.03) and axial length (correlation = −8.52, P = 0.02). A decrease in subfoveal choroidal thickness of 0.62 μm/year was found by regression analysis. CONCLUSION: Our study provides normative database and topographic profile of choroidal thickness in the normal Asian Indian eyes using RTVue XR 100 OCT.

Publisher

Medknow

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3