CAD May Not be Necessary for Microcalcifications in the Digital era, CAD May Benefit Radiologists for Masses

Author:

Destounis Stamatia V.1,Arieno Andrea L.1,Morgan Renee C.1

Affiliation:

1. Elizabeth Wende Breast Care, LLC., Rochester, NY, USA

Abstract

Objective: The aim of this study was to evaluate the effectiveness of computer-aided detection (CAD) to mark the cancer on digital mammograms at the time of breast cancer diagnosis and also review retrospectively whether CAD marked the cancer if visible on any available prior mammograms, thus potentially identifying breast cancer at an earlier stage. We sought to determine why breast lesions may or may not be marked by CAD. In particular, we analyzed factors such as breast density, mammographic views, and lesion characteristics. Materials and Methods: Retrospective review from 2004 to 2008 revealed 3445 diagnosed breast cancers in both symptomatic and asymptomatic patients; 1293 of these were imaged with full field digital mammography (FFDM). After cancer diagnosis, in a retrospective review held by the radiologist staff, 43 of these cancers were found to be visible on prior-year mammograms (false-negative cases); these breast cancer cases are the basis of this analysis. All cases had CAD evaluation available at the time of cancer diagnosis and on prior mammography studies. Data collected included patient demographics, breast density, palpability, lesion type, mammographic size, CAD marks on current- and prior-year mammograms, needle biopsy method, pathology results (core needle and/or surgical), surgery type, and lesion size. Results: On retrospective review of the mammograms by the staff radiologists, 43 cancers were discovered to be visible on prior-year mammograms. All 43 cancers were masses (mass classification included mass, mass with calcification, and mass with architectural distortion); no pure microcalcifications were identified in this cohort. Mammograms with CAD applied at the time of breast cancer diagnosis were able to detect 79% (34/43) of the cases and 56% (24/43) from mammograms with CAD applied during prior year(s). In heterogeneously dense/extremely dense tissue, CAD marked 79% (27/34) on mammograms taken at the time of diagnosis and 56% (19/34) on mammograms with CAD applied during the prior year(s). At time of diagnosis, CAD marked lesions in 32% (11/34) on the craniocaudal (CC) view, 21% (7/34) on the mediolateral oblique (MLO) view. Lesion size of those marked by CAD or not marked were similar, the average being 15 and 12 mm, respectively. Conclusion: CAD marked cancers on mammograms at the time of diagnosis in 79% of the cases and in 56% of the cases from the mammograms with CAD applied in the prior year(s). Our review demonstrated that CAD can mark invasive breast carcinomas in even dense breast tissue. CAD marked a significant portion on the CC view only, which may be an indicator to radiologists to be especially vigilant when a lesion is marked on this view.

Publisher

Scientific Scholar

Subject

Radiology Nuclear Medicine and imaging

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司