An in vitro comparative evaluation of cyclic fatigue resistance of two rotary and two reciprocating file systems

Author:

Srikumar G. P. V.1,Gadbail Vaishnavi1,Alexander Arvind Kumar2,Nishad Geeta1,Rahane Shripriya3,Beautlin J. S.2

Affiliation:

1. Department of Conservative Dentistry and Endodontics, Triveni Institute of Dental Sciences, Hospital and Research Centre, Bilaspur, Chhattisgarh, India

2. Department of Conservative Dentistry and Endodontics, Rajas Dental College and Hospital, Tirunelveli, Tamil Nadu, India

3. Department of Conservative Dentistry and Endodontics, Rajesh Ramdasji Kambe Dental College and Hospital, Akola, Maharashtra, India

Abstract

Context: Root canal instrumentation is one of the important procedures for successful endodontic therapy. Unexpected fracture of files occurs during root canal instrumentation without any visible signs of deformation compromising the success of root canal treatment. Aims: The aim of the study was to evaluate and compare cyclic fatigue resistance (CFR) of rotary and reciprocating files in simulated canals with 45°, 60°, and 90° angle of curvature. Settings and Design: The study design was an In vitro study. Subjects and Methods: Sixty nickel–titanium files, 30 each of rotary and reciprocating files were selected and divided into four groups (n = 15) of Neoendo Flex, ProTaper Next, WaveOne Gold (WOG), and Reciproc Blue (RPB) files. Each group was further subdivided into three subgroups containing five samples each based on their use in simulated canals with 45°, 60°, and 90° angle of curvature. To simulate root canals with 45°, 60°, and 90° angle of curvature, three artificial canals were designed in a stainless steel metal block. Each file was autoclaved, immersed in 3% sodium hypochlorite (NaOCl), and coated with 17% ethylenediaminetetraacetic acid (EDTA). Each file was tested for CFR using a torque-controlled reduction handpiece by instrumenting in a simulated canal for 10 s until fracture. The cycle of autoclaving, exposure to NaOCl, EDTA, and testing of CFR for 10 s per canal as per groups and subgroups was repeated again and again until the respective file fracture. The time taken to file fracture was recorded using a digital chronometer. The time taken for each file fracture (in minutes) was multiplied by the number of rotations per minute to attain the number of cycles to failure (NCF). Statistical Analysis Used: The obtained results were subjected to statistical analysis using one-way analysis of variance and independent t-test. Results: One-way ANOVA test showed a statistically significant difference between the four groups, P < 0.001. Independent “t”-test between individual subgroups showed a statistically significant difference, as P < 0.05. Conclusions: WOG and RPB reciprocating file systems showed superior CFR, more especially in canals with abrupt 90° angle of curvature compared to both rotary file systems tested. Among rotary file systems tested, Neoendo Flex showed greater CFR than ProTaper Next.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3