Transthoracic ultrasound in the diagnosis and follow-up of ventilator-associated pneumonia

Author:

El-shinnawy Olfat M1,Metwally Mohamed1,Abdelaleem Nermeen1,R R Gharieb Dina1

Affiliation:

1. Department of Chest Diseases and Tuberculosis, Faculty of Medicine, Assiut University, Assiut, Egypt

Abstract

Abstract Context Patients in the intensive care unit (ICU) are at risk not only from their critical illness but also from secondary processes such as nosocomial infection. Pneumonia is the second most common nosocomial infection in critically ill patients. Indeed, diagnosis of ventilator-associated pneumonia (VAP) requires a high clinical suspicion combined with bedside examination, radiographic examination, microbiological analysis of respiratory secretions, and blood test. Aims This study aimed to evaluate the effectiveness and accuracy of lung ultrasound for VAP diagnosis and follow-up. Settings and design A prospective cohort study was conducted on 74 patients, with a total number of 54 with a high likelihood of VAP and 20 with a low likelihood of VAP. Methods and material Mechanically ventilated patients for 48 h or more were included. We calculated the clinical pulmonary infection score and the lung ultrasound was performed within 24 h. Statistical analysis Data were collected and analyzed using SPSS (Statistical Package for the Social Sciences, version 20, IBM, and Armonk, New York). Quantitative data were expressed as mean ±standard deviation (SD) and compared with Student’s t-test. Nominal data were given as number (n) and percentage (%). Chi2 test was implemented on such data. Results Based on the clinical pulmonary infection score (CPIS) with a cutoff point of ≥6, the sensitivity of transthoracic ultrasound was 81.5%, the specificity was 82%, and the accuracy was 81.6%. Regarding sonographic signs, the highest sensitivity was for subpleural dots of consolidation (82%), then B-lines (56%), followed by pleural effusion, and air bronchogram (both 19%). The highest specificity was for air bronchogram (100%), then B-lines, and pleural effusion (both 90%), followed by subpleural dots of consolidation (80%). The positive predictive value for transthoracic ultrasound was 92%; the area under the receiver-operating characteristic (ROC) curve (AUC) for the total ultrasound score was 0.82. Conclusions Transthoracic ultrasound is an easy bedside tool for the diagnosis and follow-up of ventilator-associated pneumonia.

Publisher

Medknow

Subject

General Medicine

Reference9 articles.

1. A study on ventilator associated pneumonia with special reference to multidrug resistant pathogens in a Tertiary care hospital;Vasanthi;PhD diss., Madras Medical College, Chennai, Tamil Nadu, India,2016

2. ‘Risk factors of ventilator-associated pneumonia in critically III patients;Wu;Front Pharmacol,2019

3. Lung ultrasound for early diagnosis of ventilator-associated pneumonia;Mongodi;Chest,2016

4. Lung ultrasound for the diagnosis of pneumonia in adults: a meta-analysis;Long;Medicine,2017

5. Diagnostic performance of trans-thoracic sonography in patients of pneumonia and pulmonary embolism;Sayed;Egypt J Chest Dis Tuberc,2016